Digital inputs 1 ... 4

Settings for digital input 1 ... 4.
 
Digital inputs 1 ... 4 are located onboard on terminal X3.
 
 
Details
The digital inputs are used for control tasks. For this purpose, the digital inputs are available as selectable triggers for functions.
The following settings are possible for the digital inputs:
–
Debounce time ①
 
–
Inversion ②
 
–
Manual I/O control ③
 
 
 
Diagnostic parameters
Display of the logic state of the digital inputs: 0x60FD.
 
Debounce time
The debounce time can be used to prevent short disturbances from being erroneously recognized as signals.
 
Inversion
Each digital input can be configured in such a way that the state pending at the terminal is logically inverted internally. This way, a closed contact, for instance, serves to deactivate an assigned function instead of activating it.
 
Manual I/O control
Each digital input can be manually overridden. After the function is activated, the actual values are "frozen". Afterwards, each digital input can be overwritten manually.
Setting:
–
Activation for all digital inputs: 0x263B:001
 
–
Entry of the individual manual values: 0x263B:002 ... 0x263B:005
 
 
Parameter
Address
Name / setting range / [default setting]
Information
0x2632:001
Inversion of digital inputs: Digital input 1
Inversion of digital input 1
0
Not inverted
1
Inverted
0x2632:002
Inversion of digital inputs: Digital input 2
Inversion of digital input 2
0
Not inverted
1
Inverted
0x2632:003
Inversion of digital inputs: Digital input 3
Inversion of digital input 3
0
Not inverted
1
Inverted
0x2632:004
Inversion of digital inputs: Digital input 4
Inversion of digital input 4
0
Not inverted
1
Inverted
0x2633:001
Digital input debounce time: Digital input 1
0 ... [0] ... 50 ms
Debounce time of digital input 1
0x2633:002
Digital input debounce time: Digital input 2
0 ... [0] ... 50 ms
Debounce time of digital input 2
0x2633:003
Digital input debounce time: Digital input 3
0 ... [0] ... 50 ms
Debounce time of digital input 3
0x2633:004
Digital input debounce time: Digital input 4
0 ... [0] ... 50 ms
Debounce time of digital input 4
0x263B:001
Digital inputs internal control: Activation
Activation of the internal control for all available digital inputs.
0
Off
1
On
0x263B:002
Digital inputs internal control: DI1 internal control
Input of the manual value for the digital inputs.
0
Off
1
On
0x263B:003
Digital inputs internal control: DI2 internal control
0
Off
1
On
0x263B:004
Digital inputs internal control: DI3 internal control
0
Off
1
On
0x263B:005
Digital inputs internal control: DI4 internal control
0
Off
1
On