Digital inputs and outputs

The following parameters serve to diagnose the digital inputs and outputs of the inverter.
 
Parameter
Address
Name / setting range / [default setting]
Information
0x282C:001
I/O diagnostic: Application level of the digital inputs
–
Read only
 
This parameter indicates the bit coded state or the digital inputs contain the setting of 0x2632:001 (Digital input 1).
Bit  16
Digital input 1
Bit  17
Digital input 2
Bit  18
Digital input 3
Bit  19
Digital input 4
Bit  20
Digital input 5
Bit  21
Digital input 6
Bit  22
Digital input 7
Bit  23
Digital input 8
Bit  24
Digital input 9
0x282C:002
I/O diagnostic: Digital output levels
–
Read only
 
Bit  16
Level of digital output 1
Bit  17
Level of digital output 2
Bit  18
Level of digital output 3
Bit  19
Level of digital output 4
Bit  20
Level of digital output 5
Bit  21
Level of digital output 6
0x60FD
Digital input status
–
Read only
 
Bit coded display of the current status of the digital inputs
Bit  0
Reserved
-
Bit  1
Reserved
Bit  2
Reserved
Bit  3
Reserved
Bit  16
Digital input 1
0 ≡ LOW level, 1 ≡ HIGH level.
Bit  17
Digital input 2
Bit  18
Digital input 3
Bit  19
Digital input 4
Bit  20
Digital input 5
Bit  21
Digital input 6
Bit  22
Digital input 7
Bit  23
Digital input 8
Bit  24
Digital input 9
0x60FE:001
Digital outputs: Digtal output status
0x00000000 ... [0x00000000] ... 0xFFFFFFFF
Bit  0
n/a
Bit  16
Digital output 1
Bit  17
Level for digital output 2
Bit  18
Level for digital output 3
Bit  19
Level for digital output 4
Bit  20
Level for digital output 5
Bit  21
Level for digital output 6
0x4016:005
Digital output 1: Terminal state
–
Read only
 
Display of the logic state of output terminal X3/DO1.
0
FALSE
1
TRUE