Parameter setting of the feedback system

The standardization for functional safety requires separate parameterization of the connected encoder system for the safety module.
Note the parameter settings required for this.
The plausibility check rejects ambiguous settings until they are correctly parameterized.
 
 
Parameter setting of the motor encoder
Standard device "Base Drive"
Safety module "Safe Drive"
Encoder system
Parameter
Setting
Parameter
Setting
Resolver at X7
Selection
automatic recognition
0x2878:001
2 = resolver
Number of pole pairs
0x2C43
encoder-dependent
0x2878:003
0x2878:003 = 0x2C43
Encoder at X8
Selection
0x2C40
1 = SinCos encoder
0x2878:001
1 = SinCos encoder
0x2C40
2 = HIPERFACE® SinCos absolute value encoder
0x2C40
6 = SSI SinCos absolute value encoder
Number of increments
0x2C42:001
encoder-dependent
0x2878:002
0x2878:002 = 0x2C42:001
HIPERFACE DSL® (OCT) at X109
Selection
0x2DE1:001
10 = HIPERFACE DSL® (OCT)
0x2878:001
3 = HIPERFACE DSL® (OCT)
 
Scaling of the encoder values
All encoder values are managed in the safety module as 32-bit values. The lower 16 bits contain the part of one motor revolution and the higher 16 bits contain the multiple of one motor revolution.
Examples
Encoder value
Calculation
Result (hex)
¼ motor revolution
65536/4
= 16384
0x0000'4000
½ motor revolution
65536/2
= 32768
0x0000'8000
1 motor revolution
1 * 65536
= 65536
0x0001'0000
2 motor revolutions
2 * 65536
= 131072
0x0002'0000
2½ motor revolutions
2 * 65536 + 65536/2
= 163840
0x0002'8000
 
Parameter
Address
Name / setting range / [default setting]
Information
0x2878:001
Safety motor encoder: System
–
Safety parameter (+Safety parameter list+)
 
Setting of the motor encoder.
0
No motor encoder
1
SinCos encoder
2
Resolver
3
HIPERFACE DSL® (OCT)
0x2878:002
Safety motor encoder: SinCos encoder PPR
1 ... [1] ... 16384
–
Safety parameter (+Safety parameter list+)
 
0x2878:003
Safety motor encoder: Number of resolver pole pairs
1 ... [1] ... 10
–
Safety parameter (+Safety parameter list+)
 
0x2878:004
Safety motor encoder: Response time encoder monitoring
–
Safety parameter (+Safety parameter list+)
 
12
12
50
50
100
100
0x2878:050
Safety motor encoder: Safety-HDSL driver state
–
Read only
 
Bit  0
State - bit 0
Bit  1
State - bit 1
Bit  2
State - bit 2
Bit  3
State - bit 3
Bit  4
Encoder error
Bit  5
Encoder warning
Bit  6
"Stuck-at" error
Bit  7
Position CRC error
Bit  8
Communication error
Bit  9
Encoder type not supported
Bit  10
Diagnostic error
Bit  11
Self-test missing
Bit  12
Supply voltage error
Bit  13
Different encoder ID
Bit  14
Status bit 14 (reserved)
Bit  15
Status bit 15 (reserved)
0x2878:051
Safety motor encoder: Safety HDSL online status 1
–
Read only
 
Bit  0
FRES
Bit  1
FIX0
Bit  2
QMLW
Bit  3
FIX0
Bit  4
FIX0
Bit  5
MIN
Bit  6
POSTX0
Bit  7
POSTX1
Bit  8
PRST
Bit  9
FIX0
Bit  10
VPOS
Bit  11
FIX0
Bit  12
FIX1
Bit  13
SCE
Bit  14
SSUM
Bit  15
SINT
0x2878:052
Safety motor encoder: Safety HDSL online status 2
–
Read only
 
Bit  0
FIX0
Bit  1
FIX0
Bit  2
QMLW
Bit  3
FIX0
Bit  4
FIX0
Bit  5
FIX0
Bit  6
POSTX0
Bit  7
POSTX1
Bit  8
PRST
Bit  9
FIX0
Bit  10
VPOS2
Bit  11
FIX0
Bit  12
FIX1
Bit  13
SCE2
Bit  14
SUM2
Bit  15
FIX0
0x2878:053
Safety motor encoder: Safety HDSL Safe summary
–
Read only
 
Bit  0
SSUM0
Bit  1
SSUM1
Bit  2
SSUM2
Bit  3
SSUM3
Bit  4
SSUM4
Bit  5
SSUM5
Bit  6
SSUM6
Bit  7
SSUM7
0x2878:054
Safety motor encoder: Safety HDSL Safe Channel 2 status
–
Read only
 
Bit  0
FIX2
Bit  1
FIX2
Bit  2
FIX2
Bit  3
FIX2
Bit  4
FIX2
Bit  5
ERR2
Bit  6
TEST2
Bit  7
TOG2
0x2878:055
Safety motor encoder: Safety HDSL encoder status ENC_ST0
–
Read only
 
Bit  0
Encoder status bit 0
Bit  1
Encoder status bit 1
Bit  2
Encoder status bit 2
Bit  3
Encoder status bit 3
Bit  4
Encoder status bit 4
Bit  5
Encoder status bit 5
Bit  6
Encoder status bit 6
Bit  7
Encoder status bit 7
0x2878:056
Safety motor encoder: Safety HDSL encoder status ENC_ST1
–
Read only
 
Bit  0
Encoder status bit 8
Bit  1
Encoder status bit 9
Bit  2
Encoder status bit 10
Bit  3
Encoder status bit 11
Bit  4
Encoder status bit 12
Bit  5
Encoder status bit 13
Bit  6
Encoder status bit 14
Bit  7
Encoder status bit 15
0x2878:057
Safety motor encoder: Safety HDSL encoder status ENC_ST2
–
Read only
 
Bit  0
Encoder status bit 16
Bit  1
Encoder status bit 17
Bit  2
Encoder status bit 18
Bit  3
Encoder status bit 19
Bit  4
Encoder status bit 20
Bit  5
Encoder status bit 21
Bit  6
Encoder status bit 22
Bit  7
Encoder status bit 23
0x2878:058
Safety motor encoder: Safety HDSL encoder status ENC_ST3
–
Read only
 
Bit  0
Encoder status bit 24
Bit  1
Encoder status bit 25
Bit  2
Encoder status bit 26
Bit  3
Encoder status bit 27
Bit  4
Encoder status bit 28
Bit  5
Encoder status bit 29
Bit  6
Encoder status bit 30
Bit  7
Encoder status bit 31
0x2878:059
Safety motor encoder: Safety HDSL encoder status ENC_ST4
–
Read only
 
Bit  0
Encoder status bit 32
Bit  1
Encoder status bit 33
Bit  2
Encoder status bit 34
Bit  3
Encoder status bit 35
Bit  4
Encoder status bit 36
Bit  5
Encoder status bit 37
Bit  6
Encoder status bit 38
Bit  7
Encoder status bit 39
0x2878:060
Safety motor encoder: Safety HDSL encoder status ENC_ST5
–
Read only
 
Bit  0
Encoder status bit 40
Bit  1
Encoder status bit 41
Bit  2
Encoder status bit 42
Bit  3
Encoder status bit 43
Bit  4
Encoder status bit 44
Bit  5
Encoder status bit 45
Bit  6
Encoder status bit 46
Bit  7
Encoder status bit 47
0x2878:061
Safety motor encoder: Safety HDSL encoder status ENC_ST6
–
Read only
 
Bit  0
Encoder status bit 48
Bit  1
Encoder status bit 49
Bit  2
Encoder status bit 50
Bit  3
Encoder status bit 51
Bit  4
Encoder status bit 52
Bit  5
Encoder status bit 53
Bit  6
Encoder status bit 54
Bit  7
Encoder status bit 55
0x2878:062
Safety motor encoder: Safety HDSL encoder status ENC_ST7
–
Read only
 
Bit  0
Encoder status bit 56
Bit  1
Encoder status bit 57
Bit  2
Encoder status bit 58
Bit  3
Encoder status bit 59
Bit  4
Encoder status bit 60
Bit  5
Encoder status bit 61
Bit  6
Encoder status bit 62
Bit  7
Encoder status bit 63
0x2879:001
Mechanical data: Motor mounting direction
–
Safety parameter (+Safety parameter list+)
 
Setting of the motor mounting direction.
0
Motor rotating CW
1
Motor rotating CCW
0x287A:001
Safety load encoder: System
–
Safety parameter (+Safety parameter list+)
 
0
No load encoder
1
Analog (SinCos/TTL)
2
Digital (SSI/bus)
0x287A:003
Safety load encoder: Gear numerator
1 ... [100] ... 65535
–
Safety parameter (+Safety parameter list+)
 
0x287A:004
Safety load encoder: Gear denominator
1 ... [100] ... 65535
–
Safety parameter (+Safety parameter list+)
 
0x287A:005
Safety load encoder: Mounting direction
–
Safety parameter (+Safety parameter list+)
 
0
As motor encoder
1
Inverted to motor encoder
0x287A:006
Safety load encoder: Position
-2147483648 ... [0] ... 2147483647 incr.
–
Safety parameter (+Safety parameter list+)
 
0x287A:007
Safety load encoder: Position status
–
Safety parameter (+Safety parameter list+)
 
0
Invalid
1
Valid
0x287A:008
Safety load encoder: Additional gear numerator
1 ... [1] ... 4294967295
–
Safety parameter (+Safety parameter list+)
 
0x287A:009
Safety load encoder: Additional gear denominator
1 ... [1] ... 4294967295
–
Safety parameter (+Safety parameter list+)
 
0x287B:001
Speed: Tolerance window (n=0)
0 ... [5] ... 16000 rpm
–
Safety parameter (+Safety parameter list+)
 
If the speed is within the tolerance window, the status "n = 0 rpm" is valid.
0x287B:002
Speed: Tolerance speed comparison
1 ... [20] ... 16000 rpm
–
Safety parameter (+Safety parameter list+)
 
0x287B:003
Speed: Current speed n_safe
–
Read only: x rpm
 
Ist-Drehzahl, ermittelt aus der Validierung von nBD und nSD. Geht in die weitere Verarbeitung der geschwindigkeitsabhängigen Sicherheitsfunktionen ein.
0x287B:004
Speed: Internal current speed nSD
–
Read only: x rpm
 
Drehzahlwert Safe-Drive, intern ermittelte Ist-Geschwindigkeit aus der Safety-Applikation
0x287B:005
Speed: Internal current speed nBD
–
Read only: x rpm
 
Drehzahlwert Base-Drive, intern ermittelte Ist-Geschwindigkeit aus der Standardapplikation
0x287B:006
Speed: Current speed difference nSD-nBD
–
Read only: x rpm
 
0x287C:001
Position: Tolerance position comparison
1 ... [8192] ... 1024000 incr.
–
Safety parameter (+Safety parameter list+)
 
0x287C:002
Position: Current position p_safe
–
Read only: x incr.
 
Ist-Position, ermittelt aus der Validierung von pBD und pSD. Geht in die weitere Verarbeitung der positionsabhängigen Sicherheitsfunktionen ein.
1-Geber-System: Der inkrementelle Positionswert hat Bezug zum Motorgeber.
2-Geber-System: Der inkrementelle Positionswert hat Bezug zum Lastgeber.
0x287C:003
Position: Internal current position pSD
–
Read only: x incr.
 
Positionswert Safe-Drive, intern ermittelte Ist-Position aus der Safety-Applikation
1-Geber-System: Der inkrementelle Positionswert hat Bezug zum Motorgeber.
2-Geber-System: Die eingestellten Getriebefaktoren werden bei der Berechnung der Positionswerte berücksichtigt.
0x287C:004
Position: Internal current position pBD
–
Read only: x incr.
 
Positionswert Base-Drive, intern ermittelte Ist-Position aus der Standard-Applikation
1-Geber-System: Der inkrementelle Positionswert hat Bezug zum Motorgeber.
2-Geber-System: Der inkrementelle Positionswert hat Bezug zum Lastgeber.
0x287C:005
Position: Current position difference pSD-pBD
–
Read only: x incr.