Source of touch probe time stamp

The Source touch probe system bus parameter is used to set the source of the touch probe time stamp. 0x5020:011
Fig. 1: Selection of the source of the touch probe time stamp
 
Parameter
Address
Name / setting range / [default setting]
Information
0x5020:011
TP1 source
The sensor source and the edge to be evaluated are selected via the parameter (rising, falling, any)
0
External source
Source: System bus
1
Digital input 1, positive edge
 
 
2
Digital input 1, negative edge
 
 
3
Digital input 1, any edge
 
 
11
Digital input 2, positive edge
 
 
12
Digital input 2, negative edge
 
 
13
Digital input 2, any edge
 
 
21
Digital input 3, positive edge
 
 
22
Digital input 3, negative edge
 
 
23
Digital input 3, any edge
 
 
31
Digital input 4, positive edge
 
 
32
Digital input 4, negative edge
 
 
33
Digital input 4, any edge
 
 
0x5021:155
System bus diagnostics: Time stamp (input value)
–
Read only: x ns
 
Time stamp of the master axis
0x5021:165
System bus diagnostics: Time stamp (output value)
–
Read only: x ns
 
Time stamp of the touchprobe source in ns selected via source TP1 0x5020:011.