LED status display

The "RDY" and "ERR" LED status displays on the front of the inverter provide some quick information about certain operating states.
 
 
"RDY" LED (blue)
"ERR" LED (red)
Status/meaning
Off
Off
Supply voltage not available.
On
On
Initialisation in progress (inverter is being started.)
Blinks (1 Hz)
Off
Safe torque off (STO) active. The inverter has been inhibited by the integrated safety system.
Safe torque off (STO)
Blinks (1 Hz)
On
Inverter inhibited, error active.
On
Off
Inverter enabled.
Motor rotates according to the specified setpoint or quick stop is active.
Both LEDs are blinking in a rapidly alternating mode
Firmware update active.
Update device firmware
Both LEDs are blinking in a very rapidly synchronous mode
"Visual tracking" function is active.
Optical device identification
 
The description of the network-specific "BUS RDY" and "BUS ERR" LEDs can be found in chapters LED status display