Configuring the "Winder Dancer" TA

For the dancer control, the web tension is generated exclusively via an upstream dancer device. The advantage of a dancer device is its compensation behaviour in the event of dynamic disturbances, e.g. those which occur during acceleration and imbalances in the reel. In this case, only the dancer position changes while the tensile force remains constant. The dancer control is used in cases where the tensile force accuracy and tensile force consistency must remain within a very small tolerance zone. In the case of the dancer control, the limits are not determined by the torque setting range, but by the mechanical design of the dancer, the dynamics (mass, friction etc.) and the speed setting range of the drive.
Dancer-controlled systems can be used to rewind and unwind the following example materials at speeds of up to 1000 [m/min]:
–
Cable
 
–
Wire
 
–
Textiles
 
–
Films
 
–
Paper
 
 
The line speed signal acts as the feedforward control. The line speed signal is multiplied by the reciprocal value of the actual diameter.
 
In the case of the dancer control, the drive is operated in speed control mode. The dancer position is recorded and compared to the setpoint position. If a deviation is detected, the dancer control corrects the speed setpoint.
Fig. 1: Schematic diagram of a winding drive
 
Fig. 2: Signal flow of the Winder Dancer TA
 
Source of the master value
When changing the parameter, the inverter must be inhibited. Disable operation
 
The master values for the technology application come from a variety of sources. The source is selected via the Master value source parameter. 0x5020:014
The following sources can be selected:
–
System bus
 
–
Load encoder
 
–
Virtual master
 
–
Analog input 1