Dancer control
The feedforward control takes place via the line speed signal, which is multiplied by the reciprocal value of the actual diameter.
In the case of the dancer control, the drive is operated in speed control mode. The dancer position is recorded and compared to the setpoint position. If a deviation is detected, the dancer control corrects the speed setpoint.
The dancer control has a classic PI structure. The control is enabled by setting bit 18 of the control word.
0x5050:010 Bit 18
0x5050:010 Bit 18As long as bit 18 = FALSE, the system deviation remains 0 and the ramp generator for the dancer position setpoint is also loaded with the starting value 0.
In the case of a highly quantised actual dancer position, PT1 filtering can have a positive effect on the stability of the control loop. If high dynamic performance is required, dead times in the control loop must be avoided. The filter time can be optimised in the parameter PT1 filter time dancer position.
0x5052:188
0x5052:188The correcting variable of the PI controller is fed via a limiter, which makes it possible to set limits via the parameters Dancer control upper output limit and Dancer control lower output limit.
Parameters for the dancer control:
–
Dancer control upper output limit
0x5052:183
0x5052:183 –
Dancer control lower output limit
0x5052:184
0x5052:184The correcting variable has an additive effect on the main speed path setpoint. The influence of the parameter Effective dancer control influence has a multiplicative effect on the correcting variable of the PI controller and defines the correction value’s maximum permitted effect.
0x5052:176Fig. 1: Dancer control signal flow
Parameter