Dancer control

The feedforward control takes place via the line speed signal, which is multiplied by the reciprocal value of the actual diameter.
 
In the case of the dancer control, the drive is operated in speed control mode. The dancer position is recorded and compared to the setpoint position. If a deviation is detected, the dancer control corrects the speed setpoint.
 
The dancer control has a classic PI structure. The control is enabled by setting bit 18 of the control word. 0x5050:010 Bit 18
As long as bit 18 = FALSE, the system deviation remains 0 and the ramp generator for the dancer position setpoint is also loaded with the starting value 0.

In the case of a highly quantised actual dancer position, PT1 filtering can have a positive effect on the stability of the control loop. If high dynamic performance is required, dead times in the control loop must be avoided. The filter time can be optimised in the parameter PT1 filter time dancer position. 0x5052:188
The correcting variable of the PI controller is fed via a limiter, which makes it possible to set limits via the parameters Dancer control upper output limit and Dancer control lower output limit.
Parameters for the dancer control:
–
Dancer control upper output limit 0x5052:183
 
–
Dancer control lower output limit 0x5052:184
 
 


The correcting variable has an additive effect on the main speed path setpoint. The influence of the parameter Effective dancer control influence has a multiplicative effect on the correcting variable of the PI controller and defines the correction value’s maximum permitted effect.
0x5052:176
Fig. 1: Dancer control signal flow
 
Parameter
Address
Name / setting range / [default setting]
Information
0x5050:012
Set velocity
0.0000 ... [0.0000] ... 214748.3647 mm/s
Setpoint line velocity
0x5020:020
Line velocity source
0
External
1
Load encoder
3
Synchronized with master value
0x5021:152
System bus diagnostics: Velocity (input value)
–
Read only
 
Speed conductivity
0x5050:023
Dancer set position
-100.00 ... [0.00] ... 100.00 %
Setpoint dancer position
0x5050:024
Dancer control influence
0.00 ... [0.00] ... 21474836.47 %
Set the influence of the dancer controller.
0x5051:007
Evaluation line velocity - numerator
-2147483648.0000000000 ... [1.0000000000] ... 2147483647.0000000000
0x5051:008
Evaluation line velocity - denominator
-2147483648.0000000000 ... [1.0000000000] ... 2147483647.0000000000
0x5051:009
Actual line velocity
–
Read only: x.xxxx mm/s
 
The parameter is resolved with 4 decimal positions. The parameter has the unit [mm/s].
0x5051:012
Line velocity reference
0.0000 ... [1000.0000] ... 214748.3647 mm/s
0x5051:033
Effective set speed
–
Read only: x.xx rev/s
 
0x5051:096
Actual diameter
–
Read only: x.xxxx mm
 
The parameter is resolved with 4 decimal positions. The parameter has the unit [mm].
0x5052:174
Source of dancer control influence
0
External
Influence of dancer control
1
Parameter
Influence of dancer control via parameter
0x5052:175
Set dancer control influence
-21474836.48 ... [0.00] ... 21474836.47 %
0x5052:176
Effective dancer control influence
–
Read only: x.xx %
 
0x5052:177
Source of dancer set position
0
External
Setpoint position of dancer via fieldbus
1
Parameter
Setpoint position of dancer via parameter value
0x5052:178
Dancer set position
-21474836.48 ... [0.00] ... 21474836.47 %
0x5052:179
Effectice dancer set position
–
Read only: x.xx %
 
0x5052:180
Dancer set position ramp
-21474836.48 ... [1.00] ... 21474836.47 1/s
0x5052:181
Dancer control gain
-21474836.48 ... [1.00] ... 21474836.47
0x5052:182
Dancer control reset time
-2147483.648 ... [0.000] ... 2147483.647 s
0x5052:183
Dancer control upper output limit
0.00 ... [100.00] ... 200.00 %
0x5052:184
Dancer control lower output limit
-200.00 ... [-100.00] ... 0.00 %
0x5052:185
Max. deviation for reduced gain
0.00 ... [0.00] ... 21474836.47 %
0x5052:186
Dancer control reduced gain
0.00 ... [0.00] ... 21474836.47
0x5052:187
Effective dancer control set position
–
Read only: x.xx %
 
0x5052:188
Filter time dancer position
0.001 ... [0.005] ... 0.010 s
0x5052:189
Effective actual dancer position
–
Read only: x.xx %
 
0x5052:190
Dancer position raw value
–
Read only
 
0x5052:191
Dancer control output scaled actual value
–
Read only: x.xx %
 
0x5052:192
Dancer control output actual value
–
Read only: x.xxxx mm/s