Signal flow

Fig. 1: Dancer control signal flow
 
Relevant parameters of other functions
Address
Name
Default setting
Setting range
Diagnostics of analog input 1: Scaled percent value
x.xx % (Read only)
Actual velocity
- (Read only)
Line velocity source
External [0]
Selection list
Actual dancer position source
Analog input 1 [1]
Selection list
System bus diagnostics: Velocity (input value)
- (Read only)
Set velocity
0.0000 mm/s
0.0000 ... 214748.3647 mm/s
Dancer set position
0.00 %
-100.00 ... 100.00 %
Dancer control influence
0.00 %
0.00 ... 21474836.47 %
Actual dancer position
0.00
-21474836.48 ... 21474836.47
Evaluation line velocity - numerator
1.0000000000
-2147483648.0000000000 ... 2147483647.0000000000
Evaluation line velocity - denominator
1.0000000000
-2147483648.0000000000 ... 2147483647.0000000000
Actual line velocity
x.xxxx mm/s (Read only)
Line velocity reference
1000.0000 mm/s
0.0000 ... 214748.3647 mm/s
Speed controller adaption mode
Vp adaption = d² [0]
Selection list
Speed control adaption min. value
20.00 %
0.00 ... 100.00 %
Speed controller actual gain
x.xx % (Read only)
Effective set speed
x.xx rev/s (Read only)
Effective velocity for diameter calculation
x.xxxx mm/s (Read only)
Source of line velocity for diameter calculation
0
Actual diameter
x.xxxx mm (Read only)
Actual moment of inertia
- (Read only)
Acceleration compensation set torque
x.xxxx Nm (Read only)
Source of dancer control influence
External [0]
Selection list
Set dancer control influence
0.00 %
-21474836.48 ... 21474836.47 %
Effective dancer control influence
x.xx % (Read only)
Source of dancer set position
External [0]
Selection list
Dancer set position
0.00 %
-21474836.48 ... 21474836.47 %
Effective dancer control set position
x.xx % (Read only)
Filter time dancer position
0.005 s
0.001 ... 0.010 s
Effective actual dancer position
x.xx % (Read only)
Dancer position raw value
- (Read only)
Dancer control output actual value
x.xxxx mm/s (Read only)
Stored material length in dancer
0.0000 mm
-214748.3648 ... 214748.3647 mm
Filter time dancer movement
0.005 s
0.001 ... 0.010 s