0x2DE0:014
|
Overwrite bit 4 of CiA control word
|
|
|
0
|
No overwrite
|
|
1
|
Overwrite with FALSE
|
|
2
|
Overwrite with TRUE
|
|
0x500A:004
|
PLCopen status
|
|
1
|
ErrorStop
|
|
2
|
Disabled
|
|
3
|
Standstill
|
|
4
|
Stopping
|
|
5
|
DiscMotion
|
|
6
|
SyncMotion
|
|
7
|
ContMotion
|
|
8
|
Homing
|
|
10
|
Service
|
|
0x500A:005
|
Status word
|
|
Bit
0
|
Virtual mode active
|
|
Bit
1
|
Axis ready
|
|
Bit
2
|
Axis enabled
|
|
Bit
3
|
Warning active
|
|
Bit
4
|
Error active
|
|
Bit
5
|
Home position detected
|
|
Bit
6
|
Software limit switches enabled
|
|
Bit
7
|
Software limit switch positive
|
|
Bit
8
|
Software limit switch negative
|
|
Bit
9
|
Hardware limit switch positive
|
|
Bit
10
|
Hardware limit switch negative
|
|
Bit
11
|
STO active
|
|
Bit
12
|
Brake opened
|
|
Bit
13
|
Application quick stop active
|
|
Bit
14
|
Limitation active
|
|
Bit
16
|
"Following error" warning active
|
|
Bit
17
|
"Following error" error active
|
|
Bit
18
|
Homing active
|
|
Bit
19
|
Homing switch for touch probe reached
|
|
Bit
20
|
Application torque limits
|
|
Bit
21
|
Manual jog active
|
|
Bit
22
|
Standstill active
|
|
Bit
23
|
Set position reached
|
|
Bit
24
|
Software limit switches switched off
|
|
Bit
25
|
|
|
0x500A:010
|
Actual position
|
|
0x500A:011
|
Actual velocity
|
|
0x500A:012
|
Actual acceleration
|
|
0x500A:014
|
Set position
|
|
0x500A:015
|
Velocity setpoint
|
|
0x500A:016
|
Acceleration setpoint
|
|
0x500A:017
|
Torque setpoint
|
|
0x500B:005
|
Status word
|
|
Bit
1
|
Encoder ready
|
|
Bit
3
|
Warning active
|
|
Bit
4
|
Error active
|
|
Bit
5
|
Home position detected
|
|
Bit
22
|
Standstill active
|
|
0x500B:010
|
Actual position
|
The current position value is resolved with 4 decimal positions.
|
|
0x500B:011
|
Actual velocity
|
The current speed value is resolved with 4 decimal positions.
|
|
0x500B:012
|
Actual acceleration
|
|