Scaling the actual dancer position
The signal of the actual dancer position is scaled to the upper and lower dancer limit positions. This simplifies the specification of the setpoint and the monitoring of the dancer position.
The reference values for scaling must be defined during commissioning:
–
This value is the reference for the upper limit position, i.e. corresponds to +100%. On the dancer is the minimum material length.
0x5052:171
0x5052:171–
This value is the reference for the lower limit position, i.e. corresponds to -100%. On the dancer is the maximum material length.
0x5052:172
0x5052:172The reference values for scaling can be set in 2 ways:
1.
The reference values can be transferred manually to the parameters for Upper dancer end position and for Lower dancer end position if the values are known.
The reference values from the above parameters are valid if the source selection Source dancer end position is set to bit 0: "From parameter".
0x5052:173 Bit 0
The reference values from the above parameters are valid if the source selection Source dancer end position is set to bit 0: "From parameter".
0x5052:173 Bit 0 2.
The reference values can be determined via a teach function. Dancer limit position teach-in function
The dancer position is filtered by a PT1 filter with the time constant PT1 filter time dancer position.
0x5052:188
0x5052:188Fig. 1: Dialog overview "Evaluation dancer position"
Parameter
0x2636:013