Reduced controller dynamics in case of system deviations

It is possible to define a small gain in the parameter Dancer control reduced gain for the tolerance zone. 0x5052:186
 
Reduced controller dynamics at low system deviations have a positive effect on the damping behaviour of the control loop.
 
The tolerance zone is defined by specifying a permissible system deviation in the parameter Tension controller reduced gain. 0x5052:016
The system deviation corresponds to the setpoint minus the actual value.
 
Relevant parameters of other functions
Address
Name
Default setting
Setting range
Effectice dancer set position
x.xx % (Read only)
Max. deviation for reduced gain
0.00 %
0.00 ... 21474836.47 %
Dancer control reduced gain
0.00
0.00 ... 21474836.47
Effective actual dancer position
x.xx % (Read only)