Monitoring based on the dancer position
In addition to web monitoring, which operates on the basis of the direction of the diameter change, web breaks can also be considered the most likely cause of the dancer reaching the lower limit position during operation in the case of dancer position-controlled winders.
The method on which the web break monitoring is based is defined in the parameter Method of web break monitoring.
0x5051:073
0x5051:073|
Method of web break monitoring 0x5051: 073
|
Bit
|
Status
|
Information
|
|
|
0
|
Unexpected change in diameter direction + dancer in dancer end position
|
18
|
TRUE
|
A web break is detected when the Effective actual dancer position falls below the Threshold for lower dancer position when the dancer control is active.
|
|
–
The dancer reaching the lower limit position during operation indicates a web break.
–
Alternatively, the web break monitoring can also be based on detecting changes in the diameter. When the diameter changes in a direction different to the one expected, web break monitoring is triggered.
|
||||
|
1
|
Dancer in dancer end position
|
18
|
TRUE
|
A web break is detected when the Effective actual dancer position falls below the Threshold for lower dancer position when the dancer control is active.
|
|
–
The dancer reaching the lower limit position during operation indicates a web break.
–
Alternatively, the web break monitoring can also be based on detecting changes in the diameter. When the diameter changes in a direction different to the one expected, web break monitoring is triggered.
|
||||
|
2
|
Unexpected change in diameter
|
-
|
-
|
This function is described under web break monitoring based on a change in diameter direction.
|
The web break monitoring is activated by setting bit 24 = TRUE in the parameter Control signal.
0x5050:010 Bit 24
0x5050:010 Bit 24When a web break has been detected, bit 24 = TRUE is set in the parameter Status signal.
0x5050:110 Bit 24
0x5050:110 Bit 24