Status signals
Parameter
|
Address
|
Name / setting range / [default setting]
|
Information
|
|
|
0x5050:110
|
Status signals
0x00000000 ... [0x00000000] ... 0xFFFFFFFF
|
||
|
Bit
0
|
Ready for operation
|
Axis ready for switch-on.
|
|
|
Bit
1
|
Homing active
|
Homing is active.
|
|
|
Bit
2
|
Operation enabled
|
Axis is enabled.
|
|
|
Bit
3
|
Fault
|
An error is active.
|
|
|
Bit
4
|
Homing done
|
Homing was completed successfully.
|
|
|
Bit
5
|
Application quick stop active
|
Quick stop was triggered.
|
|
|
Bit
6
|
Manual jog active
|
Manual operation is active.
|
|
|
Bit
7
|
Warning
|
A warning is active.
|
|
|
Bit
8
|
Halt active
|
A stop was triggered in the application.
|
|
|
Bit
9
|
Motor control in limitation
|
The motor control is in limitation.
|
|
|
Bit
10
|
Set position reached
|
Actual position = setpoint position
|
|
|
Bit
11
|
Abort busy
|
The active movement is canceled.
|
|
|
Bit
12
|
Standstill
|
Standstill reached.
|
|
|
Bit
13
|
Direction of rotation inverted
|
Direction of rotation is inverted.
|
|
|
Bit
14
|
Brake opened
|
The holding brake is open.
|
|
|
Bit
15
|
STO active
|
Safe Torque Off is active.
|
|
|
Bit
16
|
Winder syncronized to line
|
The winder is synchronous with the line velocity.
|
|
|
Bit
17
|
Unwinding operation
|
The unwind mode is active.
|
|
|
Bit
18
|
Dancer control active
|
The dancer-controlled mode is active.
|
|
|
Bit
19
|
Status bit 19 (reserved)
|
Bit without function
|
|
|
Bit
20
|
Status bit 20 (reserved)
|
||
|
Bit
21
|
Diameter hold active
|
The diameter is being maintained.
|
|
|
Bit
22
|
Max. diameter reached
|
The maximum diameter has been reached.
|
|
|
Bit
23
|
Min. diameter reached
|
The minimum diameter has been reached.
|
|
|
Bit
24
|
Web break
|
A web break has been detected.
|
|
|
Bit
25
|
Dancer in max. position
|
The dancer is at the maximum position.
|
|
|
Bit
26
|
Dancer in min. position
|
The dancer is at the minimum position.
|
|
|
Bit
27
|
Status bit 27 (reserved)
|
Bit without function
|
|
|
Bit
28
|
Dancer in set position
|
The dancer is in the setpoint position.
|
|
|
Bit
29
|
Ready for motion
|
The axis is ready to move.
|
|
|
Bit
30
|
Identification active
|
An identification is active.
|
|
|
Bit
31
|
Status bit 31 (reserved)
|
Bit without function
|
|
|
0x5050:111
|
Status signals limiter
0x00000000 ... [0x00000000] ... 0xFFFFFFFF
|
Extended Safety - status of the monitoring functions
|
|
|
Bit
0
|
STO active
|
Safe torque off (STO) active.
The axis is safely switched to torqueless operation.
|
|
|
Bit
1
|
SS1 active
|
Safe stop 1 (SS1) active.
Subsequently, the drive is torqueless (STO).
|
|
|
Bit
2
|
SS2 active
|
Safe stop 2 (SS2) active.
The drive then changes to the safe operational stop (SOS).
|
|
|
Bit
3
|
SOS active
|
Safe operational stop (SOS) active.
The reached position is actively held.
|
|
|
Bit
4
|
SLS1 active
|
Safely limited speed (SLS1) active.
The travel profile changes according to the parameters set for it.
|
|
|
Bit
5
|
SLS2 active
|
Safely limited speed (SLS2) active.
The travel profile changes according to the parameters set for it.
|
|
|
Bit
6
|
SLS3 active
|
Safely limited speed (SLS3) active.
The travel profile changes according to the parameters set for it.
|
|
|
Bit
7
|
SLS4 active
|
Safely limited speed (SLS4) active.
The travel profile changes according to the parameters set for it.
|
|
|
Bit
8
|
SDpos active
|
Safe direction (SDI) active.
Only the positive direction is allowed.
|
|
|
Bit
9
|
SDneg active
|
Safe direction (SDI) active.
Only the negative direction is allowed.
|
|
|
Bit
10
|
SLI active
|
Safely limited increment (SLI) active.
A maximum permissible change in position is monitored.
|
|
|
Bit
11
|
SSE active
|
Safe stop emergency (SSE) active.
|
|
|
Bit
12
|
ES active
|
Enable switch (ES) active.
The stop functions in special mode are overridden.
|
|
|
Bit
13
|
OMS active
|
Operation mode selector (OMS) active.
Special operation is active.
|
|
|
0x5050:112
|
Actual velocity
-214748.3648 ... [0.0000] ... 214748.3647
|
Display of the actual velocity
|
|
|
0x5050:113
|
Actual position
-214748.3648 ... [0.0000] ... 214748.3647
|
Display of the actual position
|
|
|
0x5050:114
|
Error code
0 ... [0] ... 4294967295
|
Display of the current error number.
|
|
|
0x5050:115
|
Actual diameter
-214748.3648 ... [0.0000] ... 214748.3647 mm
|
Display of the actual torque
|
|
|
0x5050:116
|
Display value 1
0 ... [0] ... 4294967295
|
Display of the monitor signal "Display value 1"
Selection:
0x5050:006 |
|
|
0x5050:117
|
Display value 2
0 ... [0] ... 4294967295
|
Display of the monitor signal "Display value 2"
Selection:
0x5050:007 |
|
|
0x5051:001
|
Technology application state
–
Read only
|
||
|
-1
|
Disabled
|
||
|
0
|
Void
|
||
|
1
|
Initialisation
|
||
|
2
|
Ready for operation
|
||
|
3
|
Homing
|
||
|
4
|
MoveVel
|
||
|
5
|
MoveAbs
|
||
|
6
|
MoveRel
|
||
|
7
|
External
|
||
|
8
|
Error
|
||
|
9
|
Resume positioning
|
||
|
10
|
Manual jog
|
||
|
30
|
Acc_Dec_Sync
|
||
|
31
|
Clutch closed
|
||
|
36
|
MoveToTargetPos
|
||
|
38
|
Positioning
|
||
|
51
|
Basevelocity
|
||
|
52
|
Acc_Dec
|
||
|
60
|
ContMotion
|
||
|
65
|
Manual jog with constant line velocity
|
||
|
70
|
Synchronization
|
||
|
80
|
Moment of inertia identification
|
||
|
81
|
Diameter identification
|
||
|
90
|
Friction identification
|
||
|
100
|
Dancer control
|
||
|
110
|
Tension control
|
||
|
121
|
Operating mode CSV
|
||
|
122
|
Operating mode CST
|
||
|
123
|
Operating mode CSP
|
||
|
130
|
CyclicMotion
|
||
|
1000
|
System fault
|
||
0x5050:006