Diameter hold

If the line velocity does not correspond to the circumferential speed, the diameter cannot be calculated from the line speed and the motor speed. In this case, the calculated diameter moves in direction dmax or dmin, depending on the winding direction. Bit 21 is set when the diameter is being maintained, but not when the line speed signal does not correspond to the circumferential speed. The bit is set in parameter Status signals = TRUE. 0x5050:110 Bit 21
Bit 21 is set to TRUE in the following cases:
–
Actual line velocity in [mm/s] < Min. line velocity in [mm/s].
 
–
Actual line velocity0x5051:009
 
–
Min. line velocity0x5051:013
 
 
–
In the states:
 
–
STOP
 
–
ERROR
 
–
READY
 
–
JOGGING
 
–
SYNCLINEVEL
 
See parameter Technology application state. 0x5051:001
 
For the user-side maintenance of the diameter, control bit 21 of parameter Control signals has to be set to TRUE. 0x5050:010 Bit 21
 
Relevant parameters of other functions
Address
Name
Default setting
Setting range
Actual line velocity
x.xxxx mm/s (Read only)
Min. line velocity
1.0000 mm/s
-214748.3648 ... 214748.3647 mm/s
Winder speed
x.xx rev/s (Read only)