Monitoring the dancer position
Monitoring the dancer position is important ror the operation of the winder in the following cases:
–
The dancer control must only be enabled and the machine subsequently started when the dancer is at the setpoint position. The position is indicated by bit 28 = TRUE of the parameter Status signals.
0x5050:110 Bit 28
For the setpoint/actual comparison, the window "Dancer in target" window applies.
0x5052:197
0x5050:110 Bit 28For the setpoint/actual comparison, the window "Dancer in target" window applies.
0x5052:197–
When the dancer reaches the mechanical end position range, there is a risk of the web breaking during ongoing operation. These kind of web breaks can be prevented by monitoring whether the dancer is within at the end position range for long periods of time. Brief deflections in the direction of the dancers’ upper or lower end position do not always lead to a response from the machine control. The point that marks the start of end position range is defined via the parameters Threshold for upper dancer position and Threshold for lower dancer position.
The exceedance of the defined dancer end position is indicated in status bits bit 25 = TRUE and bit 26 = TRUE.
Parameter