0x500A:035
|
Motor mounting direction
–
Setting can only be changed if the inverter is disabled.
|
If the parameter is set to CCW, a positive motion of the machine is inverted
so that the direction of rotation of the motor becomes negative.
|
|
false
|
CW
|
CW : Clockwise rotating motor = positive machine direction
|
|
true
|
CCW
|
CCW : Counter-clockwise rotating motor = negative machine direction
|
|
0x500B:035
|
Load encoder mounting direction
–
Setting can only be changed if the inverter is disabled.
|
The mounting direction of the additional load encoder is set in this parameter.
|
|
false
|
CW
|
CW : Clockwise rotating motor = positive machine direction
|
|
true
|
CCW
|
CCW : Counter-clockwise rotating motor = negative machine direction
|