Source of quick stop

A quick stop can be requested via the control word or via a digital input. Use the Source for quick stop parameter to select which input is used. 0x5020:007
Fig. 1: Selection for quick stop
 
Parameter
Address
Name / setting range / [default setting]
Information
0x5020:007
Application quick stop source
Selection of the signal source for activating the quick stop.
0
FALSE
1
TRUE
2
Digital input 1
3
Digital input 2
4
Digital input 3
5
Digital input 4