Conditioning of the encoder signal

For further processing of encoder values in the technology application, it might be necessary to condition the value so that interference within the signal does not detrimentally affect the coupling.
The following separately adjustable filters are available for conditioning the actual value:
 
Parameter
Address
Name / setting range / [default setting]
Information
0x500B:065
Filter cycles of actual velocity
1 ... [1] ... 100
0x500B:066
Filter cycles of actual position
1 ... [1] ... 100