Parameterization of the coupling / decoupling to the PCS
Coupling, decoupling and re-coupling are carried out along the path of the conveyor belt. The coupling phase can be executed by linking profiles. The coupling path is defined between the start and end points on the conveyor belt.
|
At least one Geometry command must be activated to define the coupling path. |
Coupling or decoupling
For coupling the commands:
-
L_TC2P_CmdSyncInStart
-
L_TC2P_CmdSyncEnd
-
L_TC2P_ConveyorTrackingObject
-
L_TC2P_RotaryTrackingObject
-
At least one Geometry command (e.g. L_TC2P_CmdMoveLinearAbsolute) required.
The TCP is synchronized with the dynamic PCS after the clutch curve has been run. This means that the TCP is synchronized with the conveyor belt or rotary table. The PCS coordinate system used is read from the first geometry command.
-
PCS_1 … PCS_16: Product Coordinate System (1 … 16)
|
All the assigned Geometry - command for defining the coupling path must be in the same coordinate system. |
Link to the tracking object
The zero point of the generated dynamic PCS coordinate system is set exactly to the connected tracking object L_TC2P_TrackingObject. For this purpose, the tracking object L_TC2P_ConveyorTrackingObject or L_TC2P_RotaryTrackingObject must be connected to the itfTrackingObject input of the L_TC2P_CmdSyncInStart command.
Coupling
The tracking function for coupling or decoupling requires two commands:
-
L_TC2P_CmdSyncInStart
-
L_TC2P_CmdSyncEnd
By calling the Execute method of the command L_TC2P_CmdSyncInStart the start of the coupling path is defined. The following group commands (e.g. L_TC2P_CmdMoveLinearAbsolute) define the coupling path and must be defined in the same coordinate system PCS1, .... or PCS16..
Coupling or decoupling is performed along the path of the contour traversed. The target point of the coupling is defined by calling the Execute() method of the L_TC2P_CmdSyncEnd command.
|
0 |
Start clutch engagement |
|
1 |
Define geometry. Synchronization is performed along the path. |
|
2 |
Complete the coupling |
|
Complete the coupling. |
Furthermore, the parameter lrOffset > 0 at the input of the L_TC2P_CmdSyncInStart command can be used to specify that the coupling curve is only started with a path offset and not immediately with the start of the movement from the subsequent geometry command.
The parameter lrOffset > 0 at the input of the command L_TC2P_CmdSyncEnd is used to define the path offset for the point from which decoupling must be completed before the target point of the last geometry command from the coupling path is reached.
The offsets are set relative to the start point or target point and also across segments!
WARNING
The definition of the lrOffset of the commands L_TC2P_CmdSyncInStart and L_TC2P_CmdSyncEnd verkürzen den shortens the coupling path along the path. With the shortening of the coupling path, higher acceleration and deceleration peaks are achieved in the axes of the kinematics.
-
The high acceleration and deceleration peaks in the axes can lead to destruction of the kinematics.
Decoupling
For decoupling the following commands are required:
-
L_TC2P_CmdSyncOutStart
-
L_TC2P_CmdSyncEnd
-
At least one Geometry command (e.g. L_TC2P_CmdMoveLinearAbsolute) is required
After the clutch curve has been run, the TCP is desynchronized from the dynamic PCS. This means that the TCP is no longer synchronized with the conveyor belt/ rotary table. The coordinate system used for the desynchronization is read from the first geometry command.
By calling the Execute() method of the command L_TC2P_CmdSyncOutStart the start of the coupling is defined. The decoupling takes place along the path. For this at least one order for a Geometry command (e.g. L_TC2P_CmdMoveLinearAbsolute) must be made. The target point of the coupling is defined by calling the method Execute() of the command L_TC2P_CmdSyncEnd
|
0 |
Start decoupling. |
|
1 |
Define geometry. Desynchronization is performed along the path. |
|
2 |
Complete the decoupling. |
Furthermore, the parameterization lrOffset > 0 at the input of the command L_TC2P_CmdSyncOutStart can be used to specify that the coupling curve is only started with a path offset and not immediately with the start of the movement from the subsequent geometry command.
The parameter lrOffset > 0 at the input of the command L_TC2P_CmdSyncEnd defines the path offset for the point from which decoupling must be completed before the target point of the last geometry command from the coupling path is reached.
The offsets are set relative to the start point or target point and also across the segments.
WARNING
The definition of the lrOffset of the commands L_TC2P_CmdSyncInStart and L_TC2P_CmdSyncEnd shortens the coupling path along the path. With the shortening of the coupling path, higher acceleration and deceleration peaks are achieved in the axes of the kinematics.
-
The high acceleration and deceleration peaks in the axes can lead to destruction of the kinematics.