Downloading a device application
To download a complete device application, the data source must be known.
The following data sources are possible:
-
Linked offline device
-
File
-
Other offline device
Downloading a device application from a linked offline device
Prerequisite
There must be a link between an offline device and an online device.
How you can link an offline device with an online device is described in the section Change selection between linked devices.
To transfer the device application from a linked offline device:
-
In the device list, select the online device to which the device application is to be transferred from the linked offline device.
-
Press the Download button.
-
The dialogue of the same name opens.
-
-
Selectdevice application (without safe parameter set).
-
Specifythe linked offline device as the source for the device application to be downloaded.
-
Press the Next button.
The Transfer device application to device dialogue that opens contains
-
one or more error or warning messages, if applicable. A warning message appears if, for example, the parameter set to be transferred also contains motor and / or PC communication parameters that are overwritten in the online device.
-
further selection options in the form of checkboxes.
-
-
Check the checkboxes available for selection:
The visibility of the checkboxes depends on the selected online device. It may differ from the following list.
Before data transfer: "Lock controller". If the checkbox is greyed out, the user has no influence on preventing the controller lock from being set. It can be selected if it is not absolutely necessary to set the controller lock.
After the transfer: "Enable controller".
After transfer: "Save parameter set in device" is for information purposes only, as a device application always contains a parameter set that is saved after downloading.
-
Press the Start button.
-
The transfer progress is displayed in a new window.
-
The window closes automatically when the download of the device application has been completed without errors and the online device has restarted.
-
The window remains open as long as the transfer is not completed and also if errors occur during the transfer. The user can close the window by clicking the Close button. The unfinished transfer must be restarted after the error sources have been eliminated.
-
This completes the download of a device application to the online device.
Downloading a device application from a file
A device application can be transferred from a file to a selected online device contained in the device list .
Downloading the device application is supported for devices that receive further data in addition to the parameter set. For devices that can only be parameterised, only downloading the parameter set is supported.
Prerequisite
Downloading a device application from a file is only possible if
-
the storage location of the file is accessible for the "EASY Starter".
-
the file to be transferred has the file type *.lda.
To transfer the device application from a file:
-
In the device list, select the online device to which the device application is to be transferred.
-
Press the Download button.
-
The dialogue of the same name opens.
-
-
Selectdevice application (without safe parameter set).
-
Specify thefile as the source for the data to be downloaded.
-
Press the Next button.
-
Select storage location and file (file type *.lda)
-
Press the Open button.
The dialogue Write device application to device that opens contains
-
one or more error or warning messages, if applicable.
-
further selection options in the form of checkboxes.
-
-
Check the checkboxes available for selection:
-
The visibility of the checkboxes depends on the selected online device. It may differ from the following list.
-
Before data transfer: "Lock controller". If the checkbox is greyed out, the user has no influence on preventing the controller lock from being set. It can be selected if it is not absolutely necessary to set the controller lock.
-
After the transfer: "Enable controller".
-
After transfer: "Save parameter set in device" is for information purposes only, as a device application always contains a parameter set that is saved after downloading.
-
-
Press the Start button.
-
The transfer progress is displayed in a new window.
-
The window closes automatically when the download of the device application has been completed without errors and the online device has restarted.
-
The window remains open as long as the transfer is not completed and also if errors occur during the transfer. The user can close the window by clicking the Close button. The unfinished transfer must be restarted after the error sources have been eliminated.
-
This completes the download of the device application from a file.
Downloading a device application from an offline device
A device application can be transferred from an offline device that is available in the device list to an online device.
Please note that this function is not supported for online devices from the Lenze product range "Controllers" (e.g. Controller 3200 C, Controller p500).
To download the device app from an offline device:
-
In the device list, select the online device to which the device application is to be transferred.
-
Press the Download button.
-
The dialogue of the same name opens.
-
-
Selectdevice application (without safe parameter set) of an offline device.
-
Selectother offline device( s).
Observe the note that appears in the dialogue.
-
Press the Next button.
-
A new window opens to select the offline device.
-
-
Select an offline device from the selection directory.
-
Information about the selected offline device is displayed in the lower part of the window.
-
-
Press the OK button.
The Transfer device application to device dialogue that opens contains
-
one or more error or warning messages, if applicable. A warning appears if, for example, the device application to be transferred is different from the one in the online device. In this case, the device application in the online device is switched.
-
further selection options in the form of checkboxes.
-
-
Check the checkboxes available for selection:
The visibility of the checkboxes depends on the selected online device. It may differ from the following list.
-
Before data transfer: "Lock controller". If the checkbox is greyed out, the user has no influence on preventing the controller lock from being set. It can be selected if it is not absolutely necessary to set the controller lock.
-
After the transfer: "Enable controller".
-
After transfer: "Save parameter set in device" is for information purposes only, as a device application always contains a parameter set that is saved after downloading.
-
-
Press the Start button.
-
The transfer progress is displayed in a new window.
-
The window closes automatically when the download of the device application has been completed without errors and the online device has restarted.
-
The window remains open as long as the transfer is not completed and also if errors occur during the transfer. The user can close the window by clicking the Close button. The unfinished transfer must be restarted after the error sources have been eliminated.
-
This completes the download of the device application in the offline device.