Exchanging parameter sets with the "PLC Designer"

In the use case described here, the life cycle of a machine begins with the planning and implementation of a PLC project using the "PLC Designer". The subsequent commissioning in the life cycle is carried out with the "EASY Starter".

Due to the use of two engineering tools, the data exchange between the two is of interest and is divided into the following phases:

  • Creation of the PLC project

  • Transfer of data from the "PLC Designer" to the "EASY Starter"

  • Transferring data from the "EASY Starter" to the "PLC Designer"

Creation of the PLC project

The "PLC Designer" is used to create a PLC project for a programmable device, e.g. Inverter i950.

The PLC project comprises

  • the PLC programme,

  • the definitions of user parameters (option),

  • and the parameter values.

Transfer of data from the "PLC Designer" to the "EASY Starter"

During commissioning or servicing, certain parameter values are optimised with the "EASY Starter". As a prerequisite, the parameters from the "PLC Designer" project must be made available for the "EASY Starter".

  • This is how you transfer the data if an online device is available:

  1. Transfer the PLC project to the online device using the "PLC Designer".

    • The boot project is created.

  2. Switch "Network On" of the online device.

  3. Add online device in the "EASY Starter".

  • This is how you transfer the data when an offline device is available:

  1. Export the project file (*.lda) from the "PLC Designer" using the EASY Export function.

  2. Open the project file (*.lda) with the "EASY Starter".

Transferring data from the "EASY Starter" to the "PLC Designer"

The optimised parameter values are fed back from the "EASY Starter" into the original PLC project of the "PLC Designer" after commissioning.

  • This is how you transfer the data if parameter values have been changed in an online device:

  1. Upload the parameter set with the "EASY Starter".

  2. Save the uploaded file in "*.gdc" format.

  3. Fulfil the requirements for transferring the file to the "PLC Designer".

    • Compile the project beforehand and generate code ('Build', 'Generate code').

    • The "PLC Designer" must be offline. (Logout')

    • Exactly one element must be selected as a "Device" in the project tree.

    • The selected"Device" must support the EASY Import function. This function is not available for all device series.

    1. Import the saved file in *.gdc format into the project using the "PLC Designer"

  • This is how you transfer the data if values have been changed in an offline device:

  1. Export a file in *.gdc format with the "EASY Starter".

  2. Use the EASY Import function of the "PLC Designer" to import the exported file into the project.