Specify master offset

With a mechanical cam, the master offset corresponds to the torsion of the x shaft around an angle in relation to the master shaft.

Master offset with a mechanical cam

The x position (input position for the curve function) results from the sum of the master axis position (Master_Pos) and the lrSetOffsetPosX offset.

 WARNiNG!

Injury to persons

Risk of injury is caused by unpredictable motor movements (especially by reversing direction of rotation)

Possible consequences

Death or severe injuries

Protective measures

  • Reversing is allowed during the compensating movement if the eAllowedDirection parameter is set to 0 (both).

  • If reversing during the compensating movement should be inhibited, the eAllowedDirection parameter must be set to 1 (positive) or the eAllowedDirection parameter must be set to 2 (negative).

Signal characteristic

Range

lrSetOffsetPosX

Description

A

0

The cam is executed.

B

50

Red curve: If eOffsetModeX is set to 1 (instant absolute), the offset is also immediately connected to the x position.

Blue curves: If eOffsetModeX is set to 2 (profile generator absolute), the offset is also connected to the x position via the ramp generator.

C

50

The x axis follows the master axis with the position offset.