Specify master offset
With a mechanical cam, the master offset corresponds to the torsion of the x shaft around an angle in relation to the master shaft.

Master offset with a mechanical cam
The x position (input position for the curve function) results from the sum of the master axis position (Master_Pos) and the lrSetOffsetPosX offset.
WARNiNG!
Injury to persons
Risk of injury is caused by unpredictable motor movements (especially by reversing direction of rotation)
Possible consequences
Death or severe injuries
Protective measures
-
Reversing is allowed during the compensating movement if the eAllowedDirection parameter is set to 0 (both).
-
If reversing during the compensating movement should be inhibited, the eAllowedDirection parameter must be set to 1 (positive) or the eAllowedDirection parameter must be set to 2 (negative).
Signal characteristic
|
Range |
lrSetOffsetPosX |
Description |
|---|---|---|
|
A |
0 |
The cam is executed. |
|
B |
50 |
Red curve: If eOffsetModeX is set to 1 (instant absolute), the offset is also immediately connected to the x position. Blue curves: If eOffsetModeX is set to 2 (profile generator absolute), the offset is also connected to the x position via the ramp generator. |
|
C |
50 |
The x axis follows the master axis with the position offset. |