L_TS2P_scSF_FlexCamHigh

Structure of the signal flow

The contents of the L_TS2P_scSF_FlexCamHigh structure are read-only and provide a practical diagnostic option within the signal flow ( Signal flow diagram).

Designator

Data type

Description

MP_lrSetMasterPos

LREAL

Setpoint position of the master axis.

The position is read directly from the AXIS_REF structure.

  • Unit: units

MP_xInternalControlActive

BOOL

InternalControl is enabled via the visualization.

MP_lrSetMasterPos

LREAL

Setpoint position of the master axis.

The position is read directly from the L_MC1P_IAXIS_REF_MASTERVALUES structure.

  • Unit: units

MP_lrSetMasterVel

LREAL

Setpoint velocity of the master axis.

The velocity is read directly from the L_MC1P_IAXIS_REF_MASTERVALUES structure.

  • Unit: units/s

MP_lrSetClutchPosOut

LREAL

Output setpoint position of the clutch.

  • Unit: units

MP_lrSetClutchVelOut

LREAL

Output setpoint velocity of the clutch.

  • Unit: units/s

MP_FindClutchXPosActive

BOOL

The determination of the x-position of the cam profile corresponding to the current axis setpoint position is active.

 

MP_FindClutchXPosDone

BOOL

The determination of the x-position of the cam profile corresponding to the current axis setpoint position is completed.

MP_lrConvertMasterToXPos

LREAL

Calculated x-axis position.

This position is determined from the master-axis position as well as the slave offset and slave scaling factor.

  • Unit: units

MP_lrCamProfilerPosOut

LREAL

Y position from the cam generator.

  • Unit: units

MP_lrConvertYToSlavePos

LREAL

Resulting slave-axis position after the clutch function.

This position is determined from the y-axis position as well as the master offset and master scaling factor.

  • Unit: units

MP_lrSetXPos

LREAL

Position of the x-axis according to the cam profile.

Note: This output only shows valid values in the "CAMMING" state. In all other states, it is deactivated (value = 0).

  • Unit: units

MP_lrSetXVel

LREAL

Velocity of the x-axis according to the cam profile.

Note: This output only shows valid values in the "CAMMING" state. In all other states, it is deactivated (value = 0).

  • Unit: units/s

MP_lrSetXAcc

LREAL

Acceleration of the x-axis according to the cam profile.

Note: This output only shows valid values in the "CAMMING" state. In all other states, it is deactivated (value = 0).

  • Unit: units/s²

MP_lrSetYPos

LREAL

Position of the y-axis according to the cam profile.

Note: This output only shows valid values in the "CAMMING" state. In all other states, it is deactivated (value = 0).

  • Unit: units

MP_lrActYPos

LREAL

Current position of the y-axis.

The value is converted from the current speed of the slave axis into the y-axis.

Note: This output only shows valid values in the "CAMMING" state. In all other states, it is deactivated (value = 0).

  • Unit: units

MP_lrSetYVel

LREAL

Velocity of the y-axis according to the cam profile.

Note: This output only shows valid values in the "CAMMING" state. In all other states, it is deactivated (value = 0).

  • Unit: units/s

MP_lrActYVel

LREAL

Current velocity of the y-axis.

The value is converted from the current speed of the slave axis into the y-axis.

Note: This output only shows valid values in the "CAMMING" state. In all other states, it is deactivated (value = 0).

  • Unit: units/s

MP_lrSetYAcc

LREAL

Acceleration of the y-axis according to the cam profile.

Note: This output only shows valid values in the "CAMMING" state. In all other states, it is deactivated (value = 0).

  • Unit: units/s²

MP_xEndOfProfPositive

BOOL

Last cycle in the current cam profile with positive master speed.

  • The current values are extrapolated for detection.

  • The signal is active for one clock cycle.

FALSE äTRUE

The x-curve position jumps to the next or previous profile pulse.

FALSE

No cycle transition has occurred.

MP_xEndOfProfNegative

BOOL

Last cycle in the current cam profile with negative master speed.

  • The current values are extrapolated for detection.

  • The signal is active for one clock cycle.

FALSE äTRUE

The x-curve position jumps to the next or previous profile pulse.

FALSE

No cycle transition has occurred.

MP_lrSlaveMaxPos

LREAL

Maximum position of the slave axis.

  • Unit: units

This value is determined from the cam profile applied to the technology module. The parameters lrMasterMaxVel (master speed) and lrMasterMaxAcc (master acceleration) are included in the calculation.

The calculation is performed when:

  • Parameter xCalcCamBounds = TRUE

  • Parameter lrMasterMaxVel > 0 AND lrMasterMaxAcc > 0

MP_lrSlaveMinPos

LREAL

Minimum position of the slave axis.

  • Unit: units

This value is determined from the cam profile applied to the technology module. The parameters lrMasterMaxVel (master speed) and lrMasterMaxAcc (master acceleration) are included in the calculation.

The calculation is performed when:

  • Parameter xCalcCamBounds = TRUE

  • Parameter lrMasterMaxVel > 0 AND lrMasterMaxAcc > 0

MP_lrSlaveMaxVel

LREAL

Maximum velocity of the slave axis.

  • Unit: units/s

This value is determined from the cam profile applied to the technology module. The parameters lrMasterMaxVel (master speed) and lrMasterMaxAcc (master acceleration) are included in the calculation.

The calculation is performed when:

  • Parameter xCalcCamBounds = TRUE

  • Parameter lrMasterMaxVel > 0 AND lrMasterMaxAcc > 0

MP_lrSlaveMaxAcc

LREAL

Maximum acceleration of the slave axis.

  • Unit: units/s²

This value is determined from the cam profile applied to the technology module. The parameters lrMasterMaxVel (master speed) and lrMasterMaxAcc (master acceleration) are included in the calculation.

The calculation is performed when:

  • Parameter xCalcCamBounds = TRUE

  • Parameter lrMasterMaxVel > 0 AND lrMasterMaxAcc > 0

MP_FindClutchXPosDone

LREAL

 

The determination of the x-position of the cam profile corresponding to the current axis setpoint position is completed.

MP_lrSetCamPosOut

LREAL

Y setpoint position of the cam profile.

  • Unit: units

MP_lrSetCamAccOut

LREAL

Y setpoint velocity of the cam profile.

  • Unit: units/s

MP_lrSetSyncInPosOut

LREAL

Y setpoint acceleration of the cam profile.

  • Unit: units/s

MP_lrSetSyncInVelOut

LREAL

Setpoint velocity of the sync function.

  • Unit: units/s

MP_lrSetFollowerPosIn

LREAL

Setpoint position of the position follower.

  • Unit: units

MP_lrSetFollowerVelIn

LREAL

Setpoint velocity of the position follower.

  • Unit: units/s

MP_xInternalControlActive

BOOL

The technology module is currently controlled via the InternalControl function (visualization template). Commands via the TM interface are ignored.