QSP application

Prerequisite

  • The axis is enabled (xReadyForMotion = TRUE).

Execution

With a rising edge (FALSEäTRUE) at the xQSPApplication input, the current movement of the axis is interrupted and the axis is brought to a standstill on the basis of its last current speed value on the QSP application deceleration ramp. The parameter for the QSP application deceleration ramp is set in the AXIS REF.

If this drive is the master of one or more other drives, another stop function such as HALT or ABORT should be used to stop the entire master system. Otherwise, position jumps may occur when activated due to the control changeover in the sequence drives.

Travel diagram

No

xQSP
Application

xQSPActive

xConstant

Velocity

eTMState

Info

B

FALSEäTRUE

FALSEäTRUE

TRUEäFALSE

MOVEVELW

STOP

The speed setpoint of the axis is set to the last current speed and brought to a standstill via the QSP deceleration ramp.

Parameters to be set

The parameters for "QSP Application" can be found in the AXIS_REF in subindex 48 and 49.

The manual jog parameters from the PLC program can also be written via the L_MC1P_SetBasicParameter block.