Outputs
Basic functions
|
Designator Data type |
Description |
|
|---|---|---|
|
xReadyForOperation BOOL |
The axis is faultless. The DC bus voltage is available. "Safe Torque Off" (STO) is not active. |
|
|
xOperationEnabled BOOL |
The axis is enabled. The brake is released. |
|
|
xReadyForMotion BOOL |
The axis is enabled and faultless. The brake is released. |
|
|
xError BOOL |
TRUE |
There is an error in the technology module. |
|
xWarning BOOL |
TRUE |
There is a warning in the technology module. |
|
eErrorID |
ID of the error or warning message if xError = TRUE or xWarning = TRUE. Here you can find information on error and warning messages: L_IE1P_Error |
|
|
xSTOActive BOOL |
TRUE |
"Safe Torque Off" (STO) was enabled and is active. The axis is torque-free and the inverter is inhibited. |
|
xQSPActive BOOL |
TRUE |
The xQSPApplication input is set to TRUE. The technology module is in the "STOP" state, the axis is brought to a standstill. The output is reset as soon as the axis is at a standstill. |
|
xAbortBusy BOOL |
TRUE |
The function activated is aborted by the xAbort input. |
|
xAbortDone BOOL |
TRUE |
The activated function is aborted by the xAbort input. |
|
xJoggingBusy BOOL |
TRUE |
The manual jog function is active. The technology module is in the "JOGGING" state. |
|
xHomingBusy BOOL |
TRUE |
Homing is executed. The technology module is in the "HOMING" state. |
|
xHomingDone BOOL |
TRUE |
Homing has been completed successfully. |
|
xIsHomed BOOL |
TRUE |
The axis has been referenced ("Reference known"). xIsHomed may only be evaluated when the xAxisAvailable status is reported. |
|
eTMState |
Current state of the technology module |
|
|
scStatusBasicMotion |
Structure of the status data of the function block |
|
|
lrActVel LREAL |
Current velocity
|
|
|
lrSetVelOut LREAL |
Setpoint speed
|
|
|
lrActPos LREAL |
Actual position
|
|
|
lrSetPosOut LREAL |
Setpoint position
|
|
|
lrActFollowingError LREAL |
Current following error
|
|
Technology functions
|
Identifier Data type |
Description |
|
|---|---|---|
|
scSignalFlow |
Variables summarised in a structure that can be used to tap into measurement points in the signal flow of the technology module. |
|
|
xFollowVelocityBusy BOOL |
TRUE |
Velocity follower mode is active |
|
xFollowTorqueBusy BOOL |
TRUE |
Torque follower mode is active |
|
xVelLimitActive BOOL |
TRUE |
The velocity limits in torque follower mode on lrVelocityLowLimit or lrVelocityHighLimit is active. |
|
xAccDecLimitActive BOOL |
TRUE |
The acceleration / deceleration in velocity follower mode is limited to lrAccVelFollower / lrDecVelFollower. |
|
xTorqueInTarget BOOL |
TRUE |
The actual torque value is within the lrTorqueWindowSize around the filtered torque setpoint value. |
|
lrActTorque LREAL |
Current torque
|
|
|
lrSetTorqueOut LREAL |
Setpoint torque
|
|