FAST Motion and FAST Technology modules

Case 1: Standard technology modules

  • Configuration: FAST Toolbox = 100 AC

  • Total "Application Credit" of all users: 300 AC

  • Credit on the SD card: 300 AC

  • Calling up the FAST technology module CrossCutter (requirement: 100 AC)

Result:

  • The FB is commissioned correctly and the axis works as programmed.

  • No messages were entered in the logbook.

Case 2: Standard technology modules plus one FAST technology module without configured "Application Credit"

  • Configuration: As case 1

  • In addition, the FB TablePositioning is called up for another axis (requirement: 25 AC).

  • The FB is commissioned correctly and axis 1 works as programmed.

Result:

  • An error message appears in the logbook stating that the "Application Credit" configured for the FAST Toolbox has been exceeded.

  • After switching the machine off and on again, an error message appears in the logbook stating that the start of the application is delayed because there is a license violation.

  • The application starts after the delay time has elapsed.

  • If the FB is not called again during the rest of the runtime of the switch-on process (there is no license violation), the application also boots without delay the next time it is switched on.

  • Each time the device is switched on, the boot-up time is extended until the maximum delay time of 20 minutes is reached.

Case 3: Permanent call of the FAST PLCopen without sufficient "Application Credit" on the SD card

  • Configuration: As case 1

  • The FB MoveAbsolute is also called up for axis 1.

  • The FB is commissioned correctly and axis 1 works as programmed.

Result:

  • An error message appears in the logbook stating that the "Application Credit" configured for the FAST Toolbox has been exceeded.

  • After switching the machine off and on again, an error message appears in the logbook stating that the start of the application is delayed because there is a license violation.

  • The application starts after the delay time has elapsed.

  • Each time the device is switched on, the boot-up time is extended until the maximum delay time of 20 minutes is reached.