Read kinematic parameters

Kinematic parameters can be read via the FB MC_ReadParameter. Depending on the interface connected at the Axis input, the following parameters can be read:

  • motion axis (AXIS_REF): parameters can be read from the axis data structure or from connected inverter.

  • single axis kinematic (e.g. gantry) or axis group (AXES_GROUP_KIN): parameters of the kinematics can be read

Further information:(MC_ReadParameter)

Example call

---------------------------------------------------------------

//Declaration

VAR

ReadParaFromAxis: MC_ReadParameter;

ReadParaFromKin: MC_ReadParameter;

END_VAR

---------------------------------------------------------------

//Instance call for reading from axis (here subindex 4: PLCopen status)

ReadParaFromAxis(Axis:=GantryAxis_re, ParameterNumber:= 4, xEnable:= TRUE);

//Instance call for reading from kinematics (here Subindex 4: Kinematics status)

ReadParaFromKin(Axis:=Gantry, ParameterNumber:= 4, xEnable:= TRUE);

---------------------------------------------------------------