GDS registration

Manual

For this approach no further configuration is needed on the OPC UA Server side. All the configuration is done on GDS side. In case of the UaGDS (from Unified Automation) the UaGDSConfiguration tool can be used.

For the manual registration the GDS Client Mode parameter 0x2471:150 has to be set to 0:Disabled (default).

Automatic

The OPC UA server also offers the option of automatically registering with a GDS server. For this purpose, there is an internal client implementation in the OPC UA Server application that establishes a connection with the GDS server.

For the automatic registration the GDS Client Mode parameter 0x2471:150 has to be set to 1:Enabled Registration or to 2:Enabled Registration and Pull.

Index

Sub

Name

Default

Note

0x2471

150

GDS Client Mode

0: Disabled

0: Disabled

1: Enabled Registration

2: Enabled Registration and Pull

0x2471

156

GDS Endpoint URL

 

GDS Server address, e.g.

opc.tcp://192.168.91.48:48060

0x2471

157

GDS User

 

User name for authentication at GDS Server

0x2471

158

GDS Password

 

Password for authentication at GDS Server

Use the password dialogue in PLC Designer and EASY Starter for encrypted storage on the device.

0x2471

159

GDS Hostname Check

0: Enabled

0: Disabled

1: Enabled

For diagnosis purposes following parameters are provided:

Index

Sub

Name

Default

Note

0x2473

190

GDS Client State

0: Disabled

0: Disabled

1: Disconnected

2: Connecting

3: Register Application

4: Get Certificate Status

5: Start Signing Request

6: Finish Signing Request

7: Update Tustlist

8: Disconnecting

9: Reconnecting

0x2473

191

GDS Client Registration State

 

This parameter gives information about the registration state of the server in the GDS. It´s independent of the exchange of trust list and CA-signed certificates.

0: Unregistered

1: Registered

2: Registration Failed

It is recommended to use encrypted transport and encrypted storage whenever the Password parameter in 0x2471:158 is changed. To establish an encrypted communication with the target device use either the PLC Designer or the EasyStarter, both require a forced encryption. To edit the parameters, after a secure connection is established, only use the password dialogue on the OPC UA Client Settings tab in the PLC Designer or EASY Starter. If this method is used, the password is only stored in encrypted form on the controller. The password will not be stored in the offline parameter set.

If the parameter is set using other methods, e.g. the "Parameter list” of the tool, the password is also stored unencrypted in the offline parameter set created by the tool.

The certificate check during connection establishment between the internal GDS client and the GDS Server includes a check of the hostname in the GDS server certificate and the GDS Endpoint Url in parameter 0x2471:156. Normally this should match, because otherwise an attacker could use any trusted certificate to fake a server's identity.

Nevertheless, the check can be disabled by the parameter 0x2471:159. It´s useful if the IT infrastructure is not able to resolve hostnames via DNS server and an IP address has to be used for the GDS Endpoint Url in parameter 0x2471:156.

From a security point of view, it is not recommended to disable the hostname check.

To grant the GDS access to the OPC UA Server in case of manual or automatic registration or in case of pushing certificates, the GDS must be trusted on OPC UA Server side. This can be done manually with the Security Screen in the PLC Designer or automatically with the provisioning mode.

When registering manually in GDS and using the certificate push management, the GDS acts as an external Client. The number of external Clients is subject of license. One session is for free.