L_TV2P_scPar_StackerCraneAxisControlBase

L_TV2P_scPar_StackerCraneAxisControlBase Basic functions

Designator

Data type

Description

lrVel

LREAL

Speed for movements (MoveAbs, MoveRel, MoveVel) that are commissioned via the scCtrlBasicMotion structure.

  • Unit: units/s

  • Initial value: 3600

lrAcc

LREAL

Acceleration for movements (MoveAbs, MoveRel, MoveVel) that are commissioned via the scCtrlBasicMotion structure.

Specification of the maximum velocity variation which is to be used for acceleration.

  • Unit: units/s²

  • Initial value: 36000

lrDec

LREAL

Deceleration for movements (MoveAbs, MoveRel, MoveVel) that are commissioned via the scCtrlBasicMotion structure.

Specification of the maximum speed variation which is to be used for deceleration to standstill.

  • Unit: units/s²

  • Initial value: 100

lrJerk

LREAL

Jerk for movements (MoveAbs, MoveRel, MoveVel) that are commissioned via the scCtrlBasicMotion structure.

  • Unit: units/s³

  • Initial value: 0

eDirection

MC_DIRECTION

Traversing direction for movements (MoveAbs, MoveVel) that are instructed via the scCtrlBasicMotion structure:

  • mcCurrentDirection: Maintain current direction (only in case of modulo axes)

  • mcPositiveDirection: Positive direction

  • mcNegativeDirection: Negative direction

  • mcShortestWay: Shortest way (only in case of modulo axes)

  • mcPositiveCycle : Positive direction for modulo axes > cycle length

  • mcNegativeCycle : Negative direction for modulo axes > cycle length

  • Initial value: mcPositiveDirection

scHomeExtTP

MC_TRIGGER_REF

Transfer of an external touch probe event:

  • Only relevant for "external encoder" touch probe configuration.

  • For describing the MC_TRIGGER_REF structure, see the MC_TouchProbe function block.

L_TV2P_scPar_StackerCraneAxisControlBase Technology functions

Identifier

Data type

Description

lrTargetPos

LREAL

Absolute target position in [unit] referred to the zero position.

The target position acts for the function xExecuteProfile.

  • Unit: unit

  • Initial value: 0

eXYMode

L_TV2P_XYMode

 

Selection of the mode for the energy management acts in connection with the function xExecuteProfile.

  • Value range: 0 ... 5

  • Initial value: 0 (NotCoordinated)

 

Note:

  • The override values are taken into account for the calculation of the profiles.

  • The buffer travel for the x-axis can be activated.

  • The buffer travel for the y-axis can be activated.

  • NotCoordinated: No coordination of the axes.

  • The start commands for the x and y axes are sufficient for this function.

  • In mode 0, the status of the other axis is not relevant.

  • In modes 1 - 5, both axes must be ready to move (ReadyForMotion status).

0

NotCoordinated:

  • No coordination of the axes.

  • The function passes the start commands of the x and y axes as well as the applied override values directly.

  • The state of the other axis is not relevant.

1

SyncStartStop:

  • Simultaneous start and stop.

  • The x-axis and y-axis start simultaneously and reach the target position at the same time.

2

AsyncStartSyncStop:

  • Asynchronous start, simultaneous finish (connection power optimal).

  • y-axis = stroke travel: The non-process-determining axis is started after the acceleration phase of the process-determining axis.

  • y-axis = lowering: x- and y-axis start at the same time.

3

AsyncStartOrStop:

  • Asynchronous start or finish (total power optimal).

  • y-axis = stroke travel: The axis that does not determine the process is moved after the acceleration phase of the process-determining axis is started. x- and y-axis reach the target position at the same time.

  • y-axis = lowering: x- and y-axis start simultaneously and reach asynchronously the target position.

4

  • AsyncStartSyncStopTimeOpt: Asynchronous start, simultaneous finish (process optimized).

5

AsyncStartOrStopTimeOpt:

  • Asynchronous start or finish (process optimized).

  • Behavior as described in mode 2, however, due to the time limit superimposing acceleration or deceleration phases.

  • The priority is "process optimized".

scMinLimits

L_TV2P_Limits

x-y function: minimum values for the axis

When manipulating the profile data, do not go below the specified minimum values.

lrVel

Minimum speed

Specifies the minimum velocity at which positioning is to be performed.

  • Only positive values allowed.

  • Data type: LREAL

  • Unit: unit/s

lrAcc

Minimum acceleration

Specifies the minimum velocity change with which acceleration is to take place.

  • Only positive values allowed.

  • Data type: LREAL

  • Unit: unit/s2

lrDec

Minimum delay

Specification with which minimum velocity change is to be decelerated.

  • Only positive values allowed.

  • Data type: LREAL

  • Unit: unit/s2

scBufferData

L_TV2P_BufferData

Data for the buffer area.

Enables the buffer area to be approached at an automatically limited velocity.

lrBufferPositionPos

Position from which the buffer area is defined in positive direction of travel.

  • Data type: LREAL

  • Unit: unit

lrBufferPositionNeg

Position from which the buffer area is defined in negative direction of travel.

  • Data type: LREAL

  • Unit: unit

lrBufferVelPos

The maximum speed in the buffer area in positive direction of travel.

  • Data type: LREAL

  • Unit: unit/s

lrBufferVelNeg

LREAL

The maximum speed in the buffer area in the negative direction of travel.

  • Data type: LREAL

  • Unit: unit/s

xBufferRange

BOOL

TRUE

Buffer limits for axis are taken into account.

ascOscCompLoadScaled

ARRAY[1..2] OF L_TV2P_ValidValue

xValid

TRUE: the value lrValue is valid and active

FALSE: the value lrValue is disabled.

  • Data type: BOOL

lrValue

The base of the scaled loading:

  • Value range 0 to 1

  • Data type: BOOL

  • Default 0

ascOscCompPosScaled

ARRAY[1..4] OF L_TV2P_ValidValue

xValid

TRUE: the value lrValue is valid and active

FALSE: the value lrValue is disabled.

lrValue

The interpolation point of the scaled position of the y-axis:

  • Value range 0 to 1

  • Data type: BOOL

  • The value = 0 of the lower SW end position and value = 1 of the upper SW end position corresponds to default 0.

ascOscCompPar

ARRAY[1..2,1..4] OF L_TV2P_OscillationCompensationPar

lrEigenFrequency

Natural frequency in Hz

  • Value range 0.4 to 40.0

  • Default 0

  • Data type: LREAL

lrAmpRatio

Damping of the vibration

  • Value range 0.0 to 1.0

  • Default 0

  • Data type: LREAL

eOscCompMode

L_CT1P_OscCompMode

 

 

 

 

Vibration compensation mode

  • Initial value: 0

With the mode eOscCompMode > 0 the filter function of the axis is activated.

Switching between eOscCompMode > 0 and eOscCompMode = 0 can only be done when the axis is locked.

0 Inactive

The function is disabled.

Switching between eOscCompMode > 0 and eOscCompMode = 0 can only be done when the axis is locked.

1 FAST

Mode:

  • Shortest delay time (half oscillation period)

  • Lower robustness to parameter uncertainties

Prerequisites:

  • Knowledge of the natural frequency with an accuracy of 3 % ... 5 %

  • Knowledge of the amplitude ratio with an accuracy of about 5%.

Effect on the profile:

  • Short extension of the positioning time.

2 Medium

Mode:

  • Average delay time (whole oscillation period)

  • Increased robustness (relative to Fast mode) against parameter uncertainties

Prerequisites:

  • Knowledge of the natural frequency with an accuracy of 5 % ... 10 %

  • Knowledge of the amplitude ratio with an accuracy of about 10%.

Effect on the profile:

  • Average extension of the positioning time.

3 Robust

Even with exact parameterisation, complete suppression is not achieved, but a small residual oscillation remains.

Mode:

  • Average delay time (one oscillation period)

  • Increased robustness (in relation to the "Medium" mode) to parameter uncertainties

Prerequisites:

  • Knowledge of the natural frequency with an accuracy of 10 ... 20 %

  • Knowledge of the amplitude ratio with an accuracy of about 15%.

Effect on the profile:

  • Average extension of the positioning time.