Inputs
Basic functions
|
Designator Data type |
Description |
|
|---|---|---|
|
xEnable BOOL |
TRUE |
The function block is activated. |
|
FALSE |
The function block is deactivated. |
|
|
xEnableOperation BOOL |
TRUE |
The axis is switched to the "ready for operation" state. Controller enable is issued. |
|
xResetError BOOL |
FALSEäTRUE |
Reset axis error or software error. |
|
xQSPApplication BOOL |
TRUE |
The axis is brought to a standstill with speed control and/or held there with position control using the parameters of the QSP application.
|
|
xAbort BOOL |
FALSEäTRUE |
The active movement is cancelled and the axis is brought to a standstill profile deceleration (scPar.IrDec).
The deceleration ramp can be aborted by commissioning of a new movement (e.g. xMoveVelExecute) |
|
xJogPos BOOL |
TRUE |
Traverse axis in positive direction (manual jog). If xJogNeg is also TRUE, the eErrorID output displays the "InvalidInputJogPosJogNeg" error message and the axis stops. |
|
xJogNeg BOOL |
TRUE |
Traverse axis in negative direction (manual jog). If xJogPos is also TRUE, the eErrorID output displays the "InvalidInputJogPosJogNeg" error message and the axis stops. |
|
xHomeExecute BOOL |
FALSEäTRUE |
Start homing. The function is aborted via the xHalt input. |
|
lrOverride LREAL |
With the lrOverride factor, the defined setpoint speed is multiplied (e.g. an override value of 0.5 generates half the setpoint speed)
Note: Acceptance of the value is carried out irrespective of the status in xContinuousUpdate. |
|
|
scCtrlBasicMotion |
Structure input for controlling basic motion functions |
|
Technology functions
|
Identifier Data type |
Description |
|
|---|---|---|
|
scPar |
The parameter structure contains the parameters of the technology module. |
|
|
Axis AXIS_REF |
Reference to the axis |
|
|
scAccessPoints |
Access points that are summarised in a structure and can be used to influence the signal flow or the functions of the technology module. |
|
|
eAxisType L_TV2P_StackerCraneAxisType |
Presetting the axis type in a storage and retrieval machine (RGB) |
|
|
20 x_Axis |
The TM has the function of the x-axis. |
|
|
21 y_Axis |
The TM has the function of the y-axis. |
|
|
itfDataBus: L_TV2P_StackerCraneDataBus |
Communication link between two instances of TM L_TV2P_StackerCraneAxisControl. One instance is used to control the x-axis and the second to control the y-axis. XY coordination is possible via the data bus connection. |
|
|
xExecuteProfile BOOL |
The input is edge controlled and evaluates the rising edge. Enable absolute positioning for the axis. With scPar.eXYMode, the energy management can be set for the positioning. The TM changes to the MOVEXY state.
Note:
|
|
|
xOscComp BOOL |
This input is level controlled. Enable the Vibration compensation function.
|
|
|
TRUE |
The vibration compensation function is active for the axis. |
|
|
FALSE |
The vibration compensation function is disabled for the axis. |
|
|
lrOscCompLoadScaled |
Specification of the scaled loading for vibration compensation.
|
|
|
xExecuteBrakeTest BOOL |
The input is edge controlled and evaluates the rising edge. Function for testing the holding brake. During the brake test the TM changes to the state BRAKE_TEST.
Note: The function can be aborted via xQspApplication = TRUE. The functions xAbort = TRUE or scCtrlBasicMotion.xHalt = TRUE cannot cancel the service function! |
|
|
FALSEäTRUE |
Activate brake test for the axis
|
|
|
xExecuteBrakeGrindIn BOOL |
The input is edge controlled and evaluates the rising edge. Function for looping in the holding brake. During the grinding-in of the holding brake the TM changes to the state BRAKE_GRINDIN.
Note: The function can be aborted via xQspApplication = TRUE. The functions xAbort = TRUE or scCtrlBasicMotion.xHalt = TRUE cannot cancel the service function! |
|
|
FALSEäTRUE |
Activate brake looping for the axis.
|
|
|
xMaintenanceMode BOOL |
Enabling the maintenance mode Via xQspApplication = TRUE, xAbort = TRUE or scCtrlBasicMotion.xHalt = TRUE the maintenance mode can be interrupted. |
|
|
TRUE |
The maintenance mode is active.
DANGER! Before enabling the maintenance mode, be sure to observe the corresponding safety note in the section Maintenance Mode (Repair mode).
|
|