Inputs

Basic functions

Designator

Data type

Description

xEnable

BOOL

TRUE

The function block is activated.

FALSE

The function block is deactivated.

xEnableOperation

BOOL

TRUE

The axis is switched to the "ready for operation" state.

Controller enable is issued.

xResetError

BOOL

FALSEäTRUE

Reset axis error or software error.

xQSPApplication

BOOL

TRUE

The axis is brought to a standstill with speed control and/or held there with position control using the parameters of the QSP application.

  • The technology module remains in the "STOP" state as long as the quick stop is executed.

  • The function cannot be replaced by another function.

xAbort

BOOL

FALSEäTRUE

The active movement is cancelled and the axis is brought to a standstill profile deceleration (scPar.IrDec).

  • The state changes to "Stop".

The deceleration ramp can be aborted by commissioning of a new movement (e.g. xMoveVelExecute)

xJogPos

BOOL

TRUE

Traverse axis in positive direction (manual jog).

If xJogNeg is also TRUE, the eErrorID output displays the "InvalidInputJogPosJogNeg" error message and the axis stops.

xJogNeg

BOOL

TRUE

Traverse axis in negative direction (manual jog).

If xJogPos is also TRUE, the eErrorID output displays the "InvalidInputJogPosJogNeg" error message and the axis stops.

xHomeExecute

BOOL

FALSEäTRUE

Start homing.

The function is aborted via the xHalt input.

lrOverride

LREAL

With the lrOverride factor, the defined setpoint speed is multiplied (e.g. an override value of 0.5 generates half the setpoint speed)

  • Value range: 0 ... 1.0

  • Initial value: 1.0

Note: Acceptance of the value is carried out irrespective of the status in xContinuousUpdate.

scCtrlBasicMotion

L_TB2P_scCtrlBasicMotion

Structure input for controlling basic motion functions

Technology functions

Identifier

Data type

Description

scPar

L_TV2P_scPar_StackerCraneAxisControlBase

The parameter structure contains the parameters of the technology module.

Axis

AXIS_REF

Reference to the axis

scAccessPoints

L_TV2P_scAP_StackerCraneAxisControlBase

Access points that are summarised in a structure and can be used to influence the signal flow or the functions of the technology module.

eAxisType

L_TV2P_StackerCraneAxisType

Presetting the axis type in a storage and retrieval machine (RGB)

20 x_Axis

The TM has the function of the x-axis.

21 y_Axis

The TM has the function of the y-axis.

itfDataBus:

L_TV2P_StackerCraneDataBus

Communication link between two instances of TM L_TV2P_StackerCraneAxisControl.

One instance is used to control the x-axis and the second to control the y-axis. XY coordination is possible via the data bus connection.

xExecuteProfile

BOOL

The input is edge controlled and evaluates the rising edge.

Enable absolute positioning for the axis.

With scPar.eXYMode, the energy management can be set for the positioning.

The TM changes to the MOVEXY state.

 

Note:

  • If the xQspApplication = TRUE function is active, the start is blocked.

  • The function can be cancelled via xAbort = TRUE or scCtrlBasicMotion.xHalt = TRUE.

xOscComp

BOOL

This input is level controlled.

Enable the Vibration compensation function.

  • Activating and deactivating the function can only be done from standstill.

TRUE

The vibration compensation function is active for the axis.

FALSE

The vibration compensation function is disabled for the axis.

lrOscCompLoadScaled

Specification of the scaled loading for vibration compensation.

  • Value range: 0 ... 1 (0 ... 100 %)

  • Initial value: 0 (0 %)

xExecuteBrakeTest

BOOL

The input is edge controlled and evaluates the rising edge.

Function for testing the holding brake.

During the brake test the TM changes to the state BRAKE_TEST.

 

Note: The function can be aborted via xQspApplication = TRUE. The functions xAbort = TRUE or scCtrlBasicMotion.xHalt = TRUE cannot cancel the service function!

FALSEäTRUE

Activate brake test for the axis

  • To enable the function, the controller must be disabled (xOperationEnabled = FALSE).

xExecuteBrakeGrindIn

BOOL

The input is edge controlled and evaluates the rising edge.

Function for looping in the holding brake.

During the grinding-in of the holding brake the TM changes to the state BRAKE_GRINDIN.

 

Note: The function can be aborted via xQspApplication = TRUE. The functions xAbort = TRUE or scCtrlBasicMotion.xHalt = TRUE cannot cancel the service function!

FALSEäTRUE

Activate brake looping for the axis.

  • To enable the function, the controller must be disabled (xOperationEnabled = FALSE).

xMaintenanceMode

BOOL

Enabling the maintenance mode

Via xQspApplication = TRUE, xAbort = TRUE or scCtrlBasicMotion.xHalt = TRUE the maintenance mode can be interrupted.

TRUE

The maintenance mode is active.

 

DANGER!

Before enabling the maintenance mode, be sure to observe the

corresponding safety note in the section Maintenance Mode (Repair mode).

  • The TM is in MAINTENANCE state.

  • In this mode, the software limit switches and the hardware limit switches are deactivated.

  • The tracking error is cleared and the Jogging function is enabled.

  • The axes are only controlled in CSV mode (cyclic synchronous velocity) - velocity control without position control is active.