Maintenance Mode (Repair mode)
Danger!
With activation of the maintenance mode (xMaintenanceMode = TRUE) all monitoring functions are deactivated!
Personal injury
There is a risk of injury due to ...
-
unpredictable(e.g. unintended direction of rotation, excessive speed or jerky running);
-
passing over the SW end positions.
Possible consequences
-
Death or severe injuries
-
Machine damage
Protective measures
-
If necessary, equip systems with built-in converters with additional monitoring and protective devices in accordance with the applicable safety regulations (e.g. law on technical equipment, accident prevention regulations).
-
Keep a sufficient safety distance from the unit during commissioning.
Requirements
-
The technology module is in a fault-free state.
Inputs
The function is activated with the input xMaintenanceMode = TRUE. After starting the function, the TM "L_TV2P_StackerCraneAxisControlBase" changes to the MAINTENANCE state.
In this state
-
the monitoring of the hardware and software end positions and the following error monitoring are deactivated.
-
the axis is switched to csv mode,
-
the following error of the axis is cancelled,
-
the controller enable of follower axes can be controlled separately,
-
the brake of follower axes can be released separately,
-
the axes can be moved in manual mode via the inputs xJogPos and xJogNeg at the TM. The MAINTENANCE state is still maintained - there is no change to the Jogging state.
The external encoder is not analysed in csv mode.
Function-relevant parameters
The parameters for the Jogging function are located in the AxisRef