Maintenance Mode (Repair mode)

Danger!

With activation of the maintenance mode (xMaintenanceMode = TRUE) all monitoring functions are deactivated!

Personal injury

There is a risk of injury due to ...

  • unpredictable(e.g. unintended direction of rotation, excessive speed or jerky running);

  • passing over the SW end positions.

Possible consequences

  • Death or severe injuries

  • Machine damage

Protective measures

  • If necessary, equip systems with built-in converters with additional monitoring and protective devices in accordance with the applicable safety regulations (e.g. law on technical equipment, accident prevention regulations).

  • Keep a sufficient safety distance from the unit during commissioning.

Requirements

  • The technology module is in a fault-free state.

Inputs

The function is activated with the input xMaintenanceMode = TRUE. After starting the function, the TM "L_TV2P_StackerCraneAxisControlBase" changes to the MAINTENANCE state.

In this state

  • the monitoring of the hardware and software end positions and the following error monitoring are deactivated.

  • the axis is switched to csv mode,

  • the following error of the axis is cancelled,

  • the controller enable of follower axes can be controlled separately,

  • the brake of follower axes can be released separately,

  • the axes can be moved in manual mode via the inputs xJogPos and xJogNeg at the TM. The MAINTENANCE state is still maintained - there is no change to the Jogging state.

The external encoder is not analysed in csv mode.

Function-relevant parameters

The parameters for the Jogging function are located in the AxisRef