Brake test
The purpose of the brake test is to determine the readiness for use of the holding brake of the drive.
If the brake test is not passed, it can be concluded that the brake is not ready for operation. A successful brake test does not allow any conclusions to be drawn about the wear condition of the brake.
A passed brake test therefore only means that the brake has held during the brake test.
The execution of the brake test can be aborted prematurely. The abort is performed via xQspApplication.
-
When the brake test is aborted, the drive is locked. The brake remains applied.
Requirements
-
The technology module is in a faultless state.
-
The axis is disabled (xOperationEnabled = FALSE).
Function
During the brake test, a defined torque is applied against the closed holding brake and held for the defined time.
A brake test is not completed successfully if the motor shaft is twisted during the brake test.
In this case an error condition is switched and error message 20529 Brake_PositionDrift is displayed.
Execution
With a FALSE↗TRUE edge at the input xExecuteBrakeTest the brake test is started:
-
Setting for the x-axis:
eAxisType=x_axis -
Setting for the y-axis:
eAxisType=y_axis
State change:
TM "StackerCraneAxisControlBase" state BRAKETEST
Function-relevant parameters
The parameters are located in the AxisRef.
The parameters for the brake test refer to the motor side. Any gear unit that may be present is not taken into account.