Buffer run
Changes to the override values during an active buffer run are not taken into account.
Requirements
-
The technology module is in a faultless state.
-
The axis is enabled (xOperationEnabled = TRUE).
Function
In aisles of stacker cranes (SRM), mechanical buffers are usually placed at the end to absorb the energy of the vehicle when, due to a fault, the stacker crane (SRM) cannot decelerate.
As a rule, the path of the buffer piston is part of the normal travel path of the stacker crane, so that the positions within the buffer area are approached operationally.
To minimize the absorption of kinetic energy in the buffer, the travel profile of the RGB drive is set up so that the buffer area is approached at a reduced speed. The buffer speed is only reached at the beginning of the buffer, since braking too early unnecessarily increases the positioning time.
The buffer zones are specified in absolute sizes, i.e. the start of the buffer zones is specified in the alley measurement system.
|
A |
Traversing range of the crane |
|---|---|
|
B |
Buffer area left |
|
C |
Buffer area right |
|
❶ |
Buffer speed
|
|
❷ |
Start buffer area left lrBufferPositionPos |
|
❸ |
Start buffer area right lrBufferPositionNeg |
Execution
The buffer function is activated with the parameter xBufferRange = TRUE and deactivated with xBufferRange = FALSE. The buffers can only be activated and deactivated when the axis is at a standstill. The buffer speed is set when entering the buffer range. When leaving the buffer range, the buffer speed is not applied, i.e. the speed limit is not retained.
-
If the positioning target is within the buffer range, the profile is divided internally into two profiles so that the specified buffer speed is reached at the start of the buffer range.
-
If the positioning target is outside the buffer area OR if positioning is started in the direction "leave buffer area", the specified profile data is used; i.e. there is no manipulation of the profile data.
Function-relevant parameters
|
Identifier Data type |
Description |
|
|---|---|---|
|
scBufferData: L_TV2P_BufferData
|
Data for the buffer area |
|
|
IrBufferPositionPos |
Position from which the buffer area is defined in positive direction of travel.
|
|
|
IrBufferPositionNeg |
Position from which the buffer area is defined in negative direction of travel.
|
|
|
IrBufferVelPos |
The maximum speed in the buffer area in positive direction of travel.
|
|
|
IrBufferVelNeg |
The maximum speed in the buffer area in the negative direction of travel.
|
|