Coordinated positioning

Requirements

  • The technology module is in a faultless state.

  • The axis is enabled (xOperationEnabled = TRUE).

  • Via itfDataBus two instances of the TM L_TV2P_StackerCraneAxisControlBase are connected. One instance is used for controlling the x-axis, the second instance is used for controlling the y-axis.

Function

With the x-y function, two positioning axes can be controlled in two planes (travel drive = x and hoist drive = y) with travel profile adjustment. By selecting the mode for the intelligent coordination of lifting and travelling drive, the drives can be positioned in an energy-efficient manner without extending the positioning times.

Depending on the selected operating mode, the drives are controlled in such a way that acceleration and deceleration phases do not occur simultaneously. This means that the mode can be set to significantly reduce the maximum possible motor power in the network (optimum connected load) and the regenerative power (optimum total power).

Execution

The order for positioning is set with a FALSE-TRUE edge at the xExecuteProfile (travelling gear = x) and xExecuteProfile (lifting gear = y) input. The rising edges of the xExeucteProfile input for the x and y axes can be activated simultaneously or with a slight time delay for XY coordination. As soon as both edges of the x- and y-axis have been recognised, the calculation of the coordinated profiles begins

The coordination mode is defined via scPar.eXYMode.

Override

The override may be set for the x- and y-axis at the input of the TM L_TS2P_StackerCraneAxisControl. The override values are considered at the calculation of the profile with the assignment via xExecuteProfile. Hereby the speed of the profile is adapted. The change of the override values during a travel does not affect the current profile. They are only taken into account in the calculation with the next assignment of the profiles.

Interaction between x and y axis

If with active movement of both axes ...

  • an axis is stopped, e.g. by another Move FB, the movement of the other axis is also stopped after the ErrorStop ramp has been moved.

  • If one axis changes to the AXISERROR state, the movement of the other axis is also stopped.

In both cases, the TM "Stacker Crane" changes to the ERROR state. The error can be reset via the xResetError input of the respective TM.

Further properties of the x-y function:

  • Changes to profile data / maximum values / override during movement are not accepted.

  • If a positioning command is issued while the axes are moving, the profile data is not adjusted depending on the mode.

A buffer run can be activated for the travelling gear as well as for the lifting gear for various reasons:

  • To protect the mechanical buffers at the ends of the aisles.

  • To utilise the buffer area as a storage area. The buffer may only be approached at a reduced speed.

Change of state

With the order of a positioning the TM "StackerCraneAxisControl" changes to the state MOVEABS. Only when both axes (X and Y) have reached the target position, the state machine of the TM changes back to the STANDBY state.

The xProfileDone output becomes TRUE when the axis reaches the target position.

Selection criteria for the modes of the XY function

There are two main criteria for selection: time-optimised and performance-optimised profile.

  • Time-optimised profile.

    The aim of time-optimised profiles is not to extend the time of the profile that takes the longest. Time-optimised profiles include modes 1, 4 and 5.

  • Performance-optimised profile.

    The aim of performance-optimised profiles is to use the power of the x and y axes efficiently. Modes 2 and 3 belong to the performance-optimised profiles.

Mode 1: In this mode, time is prioritised. However, the profile should be designed to be as gentle as possible on the kinematics. Therefore, speed, acceleration and deceleration are kept as low as possible here

Mode 2: In this mode, current peaks in the connected load of the x and y axes are avoided as far as possible. This is achieved by staggering the acceleration phase of the axes. The priority of the time for the profiles is secondary and this can lead to an extension of the journey time.

Mode 3: In this mode, the total power is optimally utilised. Generative power is used wherever possible. The priority of the time for the profiles is secondary and this can lead to an extension of the journey time.

Mode 4: This mode is a combination of modes 1 and 2, where priority is given to the duration of the profile. At the same time, peaks in the connected load of the x and y axes should be avoided.

Mode 5: This mode is a combination of modes 1 and 3, in which time is prioritised. Furthermore, the connected load is optimally utilised. Where possible, regenerative energy from one axis is utilised directly as drive energy for the other axis (energy conversion).