Evaluation of the brake test

Evaluation

Message

Info

Test OK

xBrakeTestActive = TRUE↘FALSE

scSignalFlow.MP_xBrakeTestDone = TRUE

The current position of the axis remains unchanged during the

Tests within the tolerance band

parameter 124.

Test NOK

The TM switches to error state 20529 (Brake_PositionDrift).

The brake test is canceled

The current position of the axis has left the tolerance band parameter 124 during the test.

Consequence: Here, the torque is reduced, the

Controller remains enabled and the axis is held in position in CSP.

With acknowledgement of the error state via the xResetError input, the controller is disabled again if the xRegulatorOn input is set = FALSE.