Evaluation of the brake test
|
Evaluation |
Message |
Info |
|---|---|---|
|
Test OK |
xBrakeTestActive = TRUE↘FALSE scSignalFlow.MP_xBrakeTestDone = TRUE |
The current position of the axis remains unchanged during the Tests within the tolerance band parameter 124. |
|
Test NOK |
The TM switches to error state 20529 (Brake_PositionDrift). The brake test is canceled |
The current position of the axis has left the tolerance band parameter 124 during the test. Consequence: Here, the torque is reduced, the Controller remains enabled and the axis is held in position in CSP. With acknowledgement of the error state via the xResetError input, the controller is disabled again if the xRegulatorOn input is set = FALSE. |