Profile generator-based coupling

This clutch-in and declutch variant is independent of a master value movement. This means that the drive axis can also be synchronized if the master value is stationary.

Preconditions

  • The technology module is in an error-free state.

  • The axis is enabled ( xReadyForMotion = TRUE).

  • Coupling mode scPar.eSyncMode = 0 (ProfGenAbsolute)

  • xSyncIn input = TRUE

Clutching in

The drive axis clutches in from its current position to the master position via the profile generator (see parameters below). For modulo axes, the movement is executed within the slave cycle.

The resulting speed of the drive axis in the clutch-in phase results from the sum of the speed of the master axis and the allowed offset speed ( scPar.lrSyncVel parameter). In this way a coupling procedure is always carried out sub-synchronously when the clutch-in speed is set ( lrSyncVel = 0). In this case the slave axis can reach the maximum master speed.

If the clutch-in speed is set higher than '0', clutch-in takes place over the shortest clutch-in time. This means that clutching in can take place both undersynchronously and oversynchronously. The respective behaviour depends on the start conditions at the moment of the clutching in request.

The acceleration of the slave axis in the clutch-in phase also results from the sum of the acceleration of the master value and the acceleration and deceleration of the coupling (parameters scPar.lrSyncAcc , scPar.lrSyncDec ).

The eAllowedDirection parameter specifies the direction in which the clutching in procedure may be started.

Allowed clutch-in direction

eAllowedDirection

Master speed

Clutch-in possible

1: only positive direction of rotation

positive

Yes

2: only negative direction of rotation

positive

No

0: positive and negative direction of rotation

positive

Yes

1: only positive direction of rotation

negative

No

2: only negative direction of rotation

negative

Yes

0: positive and negative direction of rotation

negative

Yes

Declutching

The profile-controlled declutching brings the drive axis from its current position to a standstill with the parameters scPar.lrSyncAcc , scPar.lrSyncDec and scPar.lrSyncJerk . The scPar.lrSlaveSyncOutPos parameter defines the stopping position of the drive axis.

Clutch-in and clutch-outin coupling mode scPar.eSyncMode = 0 (ProfGenAbsolute)

No

xSyncIn

xAccDecSync

xSynchronised

eTMState

Description

A

FALSE ä TRUE

FALSE ä TRUE

FALSE

STANDBY ACC_DEC_SYNC

The clutch-in process is started. The coupling to the master value is established and the axis accelerates until it has reached the master speed.

B

TRUE

TRUE æ FALSE

TRUE

ACC_DEC_SYNC SYNCHRONIZED

The axis is synchronous with the master axis and follows the master value.

C

TRUE æ FALSE

FALSE ä TRUE

TRUE æ FALSE

SYNCHRONIZED ACC_DEC_SYNC

The declutch process is active and the axis decelerates to the declutch position.

D

FALSE

TRUE æ FALSE

FALSE

ACC_DEC_SYNC STANDBY

The axis is in the declutch position.