Profile generator-based coupling
This clutch-in and declutch variant is independent of a master value movement. This means that the drive axis can also be synchronized if the master value is stationary.
Preconditions
-
The technology module is in an error-free state.
-
The axis is enabled ( xReadyForMotion = TRUE).
-
Coupling mode scPar.eSyncMode = 0 (ProfGenAbsolute)
-
xSyncIn input = TRUE
Clutching in
The drive axis clutches in from its current position to the master position via the profile generator (see parameters below). For modulo axes, the movement is executed within the slave cycle.
The resulting speed of the drive axis in the clutch-in phase results from the sum of the speed of the master axis and the allowed offset speed ( scPar.lrSyncVel parameter). In this way a coupling procedure is always carried out sub-synchronously when the clutch-in speed is set ( lrSyncVel = 0). In this case the slave axis can reach the maximum master speed.
If the clutch-in speed is set higher than '0', clutch-in takes place over the shortest clutch-in time. This means that clutching in can take place both undersynchronously and oversynchronously. The respective behaviour depends on the start conditions at the moment of the clutching in request.
The acceleration of the slave axis in the clutch-in phase also results from the sum of the acceleration of the master value and the acceleration and deceleration of the coupling (parameters scPar.lrSyncAcc , scPar.lrSyncDec ).
The eAllowedDirection parameter specifies the direction in which the clutching in procedure may be started.
|
Allowed clutch-in direction eAllowedDirection |
Master speed |
Clutch-in possible |
|---|---|---|
|
1: only positive direction of rotation |
positive |
Yes |
|
2: only negative direction of rotation |
positive |
No |
|
0: positive and negative direction of rotation |
positive |
Yes |
|
1: only positive direction of rotation |
negative |
No |
|
2: only negative direction of rotation |
negative |
Yes |
|
0: positive and negative direction of rotation |
negative |
Yes |
Declutching
The profile-controlled declutching brings the drive axis from its current position to a standstill with the parameters scPar.lrSyncAcc , scPar.lrSyncDec and scPar.lrSyncJerk . The scPar.lrSlaveSyncOutPos parameter defines the stopping position of the drive axis.
Clutch-in and clutch-outin coupling mode scPar.eSyncMode = 0 (ProfGenAbsolute)
|
No |
xSyncIn |
xAccDecSync |
xSynchronised |
eTMState |
Description |
|---|---|---|---|---|---|
|
A |
FALSE ä TRUE |
FALSE ä TRUE |
FALSE |
STANDBY
|
The clutch-in process is started. The coupling to the master value is established and the axis accelerates until it has reached the master speed. |
|
B |
TRUE |
TRUE æ FALSE |
TRUE |
ACC_DEC_SYNC
|
The axis is synchronous with the master axis and follows the master value. |
|
C |
TRUE æ FALSE |
FALSE ä TRUE |
TRUE æ FALSE |
SYNCHRONIZED
|
The declutch process is active and the axis decelerates to the declutch position. |
|
D |
FALSE |
TRUE æ FALSE |
FALSE |
ACC_DEC_SYNC
|
The axis is in the declutch position. |