Touch probe-based master value correction

As a higher-level control loop, the master value correction controls the master position relative to a mark detected on the material (touch probe). This serves to compensate process-related mark shifts on the material with regard to the master position.

The scPar.lrSensorToolDistMaster parameter is used to specify the distance between the mark sensor and the position where the tool (e.g. cutting blade, printheads) engages the material. The determination of this parameter also determines the position of the scSignalFlow.MP_lrMarkSensorSetPos sensor within the register cycle.

The length of the register cycle is specified in the scPar.lrMarkDistMaster parameter. It corresponds to the distance of the marks.

If a mark (touch probe) occurs during the process, the detected register position is compared to the sensor position. The difference between these two positions as per the signal flow variable (measuring points) MP_lrMarkSensorSetPos and MP_lrMarkActTpPos forms the position error that is output at lrSetMarkCorrOut .

Master value correction parameterization

Œ

Parameter scPar. lrSensorToolDistMaster



Parameter scPar.lrMarkDistMaster

Inputs relevant for the function

The inputs are located in the L_TS2P_SyncAndCorrectionState function block.

  • scTPRecData_MarkSensor

Outputs relevant for the function

The outputs are located in the L_TS2P_SyncAndCorrectionState function block.

  • lrSetMarkCorrOut

Parameters relevant for the function

The parameters are located in the L_TS2P_scPar_SyncAndCorrectionState structure.

  • scPar.lrSensorToolDistMaster

  • scPar.lrMarkDistMaster

Measuring points relevant for the function

The measuring points are located in the L_TS2P_scSF_SyncAndCorrectionState structure.

  • MP_lrIntegratorRegPos

  • MP_lrCorrRegPos

  • MP_lrMarkSensorSetPos

  • MP_lrMarkActTpPos

  • MP_xMarkReceived

  • MP_lrActMarkError

  • MP_lrActMarkDist