Mark stack master value correction

The mark stack is always required if, due to the design, the sensor cannot be mounted within one cycle in front of the tool (e.g. cutting blade, printheads); i.e. scPar.lrSensorToolDistMaster > scPar.lrMarkDistMaster .

The function ensures that the detected mark is only evaluated when it is located in the cycle in front of the tool. Simply put, the mark sensor is moved virtually to the position exactly one cycle in front of the tool. The tool may be mounted a maximum of 64 cycles in front of the tool. The length of the mark stack is calculated as follows:

Mark stack length = scPar.lrSensorToolDistMaster - scPar.lrMarkDistMaster

The aim should always be to mount the mark sensor as close as possible to the tool. The farther away the mark sensor is mounted from the axis, the more changes in the material flow remain undetected, causing cutting inaccuracies.

Systematic representation of the mark register

Œ

scPar.lrSensorToolDistMaster



scPar.lrMarkDistMaster

’

Length of the mark stack

Parameters relevant for the function

The parameters are located in the L_TS2P_scPar_SyncAndCorrectionState structure.

  • scPar.lrSensorToolDistMaster , LREAL, initial value: 0 unit

  • scPar.lrMarkDistMaster , LREAL, initial value: 360 units

Signal characteristic

Signal characteristic when the mark stack is used

No

scTPRecData_MarkSensor.xValueStored

scSignal-Flow.MP_ xMarkReceived

Description

1

FALSE ä TRUE

FALSE

The first mark has occurred and is saved in the mark stack.

2

FALSE ä TRUE

FALSE ä TRUE

The first mark has exited the mark stack. The length of the mark stack can be read from the distance covered between

scSignalFlow.MP_lrSetCorrPosOut[1] and