Mark window master value correction

In the case of print images, it can happen, for example, that not only the print marks themselves but also parts of the print image or other interfering signals are located in the scanning field of the mark sensor.

A mark window can be activated to prevent the mark sensor from being triggered unintentionally. When the scPar.xEnableMarkWindowMaster parameter = TRUE, the mark window function is active.

For the master value correction to function properly when the mark window is activated, the mark window has to be taught once. That can happen in the declutched state (master value is moving, drive axis is at standstill) as well as when the drive axis is in the clutched-in state (master value and drive axis are moving).

In order for the master value correction to function properly when the mark window is activated, the mark window must be taught in once. There are two different use cases for this:

  1. Master value moves, drive axes is decoupled

  2. Master value moves, drive axes is coupled

With the input xTeachMarkWindow the teach-in function is activated. Each time a mark is detected, the mark window is placed symmetrically around the mark until the input xTeachMarkWindow is set to the value FALSE again.

In the second application, the guide position is not set but corrected via the guide value correction. This can take several product cycles before an optimum correction is achieved. This leads to greater product waste.

The mark window can be shifted via scPar.lrSetOffsetMarkWindowMaster .

Correction window relating to the position of the corrected master axis

Ž

scPar.lrMarkWindowSizeMaster



scPar.lrSetOffsetMarkWindowMaster

Inputs relevant for the function

The inputs are located in the L_TS2P_SyncAndCorrectionState function block.

  • xTeachMarkWindow

Outputs relevant for the function

The outputs are located in the L_TS2P_SyncAndCorrectionState function block.

  • xMarkWindowTeached

Parameters relevant for the function

The parameters are located in the L_TS2P_scPar_SyncAndCorrectionState structure.

  • xEnableMarkWindowMaster , BOOL, initial value: FALSE

  • lrMarkWindowSizeMaster , LREAL, initial value: 90 [unit]

  • lrSetOffsetMarkWindowMaster , LREAL, initial value: 0 [unit]

Signal characteristic

Signal characteristic when the teaching function is executed (xTeachMarkWindow = TRUE)

No.

scTPRecData_
MarkSensor.
xValueStored

xTeachMark
Window

xMarkWindow
Teached

scSignal-Flow.MP_ xMarkWindowOpen

Description

A

FALSE

FALSE ä TRUE

FALSE

FALSE

Mark window teaching is started.

B

FALSE ä TRUE

TRUE

FALSE ä TRUE

FALSE ä TRUE

The first mark after the teach process has started opens the mark window.

C

FALSE ä TRUE

TRUE

TRUE

TRUE

The mark window is open.

The next mark is detected within the mark window.

Synchronous clutch-in in coupling mode scPar.eSyncMode = 5 (Ramp_Dist)

No

scTPRecData_MarkSensor.xValueStored

scSignal-Flow.MP_ xMarkWindowOpen

Description

A

FALSE ä TRUE æ FALSE

FALSE ä TRUE

The first mark occurs within the mark window.

B

FALSE ä TRUE æ FALSE

FALSE ä TRUE

The second mark occurs within the mark window.

C

FALSE ä TRUE æ FALSE

FALSE ä TRUE

The third mark occurs within the mark window.

D

FALSE ä TRUE æ FALSE

FALSE ä TRUE

The fourth mark occurs within the mark window.