Path-based coupling
Preconditions
-
The technology module is in an error-free state.
-
The axis is enabled ( xReadyForMotion = TRUE).
-
Coupling mode scPar.eSyncMode = 2 (DistAbsolute)
-
xSyncIn input = TRUE
Clutching in
The clutch-in path is specified via the scPar.lrSlaveSyncInDist parameter. The clutch-in process begins when the master position is at a distance of scPar.lrSlaveSyncInDist in front of the current setpoint position of the drive axis. If the scPar.lrSlaveSyncInDist parameter is set to its initial value of 90 units, the clutch-in process is complete after 90 path units.
HINWEIS
In case of "Limited" axis setting:
-
The drive axis is clutched in if the master position has reached the distance of scPar.lrSlaveSyncInDist in front of the current setpoint position of the drive axis.
Declutching
The declutch path is specified via the scPar.lrSlaveSyncOutDist parameter. The declutch process begins when the drive is at a distance of scPar.lrSlaveSyncOutDist from the 0x5041:035 declutch position. If the scPar.lrSlaveSyncOutDist parameter is set to its initial value of 90 units, the declutch process is complete after 90 path units.
HINWEIS
In case of "Limited" axis setting:
-
So that the drive axis is declutched at the scPar.lrSlaveSyncOutPos declutch position, the scPar.lrSlaveSyncOutDist distance must be defined in advance.
Asynchronous (relative) clutch-in
scPar.eSyncMode = 1 (ProfGenRelative) or 3 (DistRelative)
-
If the master value is at standstill, the drive axis clutches in directly (abruptly) at its current position.
-
If the master value moves, the drive axis coupling process starts immediately. (As with a speed coupling)
After the coupling process, the offset between the position of the drive axis and the position of the master axis is constant ( scSignal-Flow.MP_lrPositionOffsetClutch ). This offset can be eliminated by setting the xSyncPosRestore input to TRUE. The parameters of the offset function then make it possible to "reduce" the offset to 0.
Inputs relevant for the function
The inputs are located in the L_TS2P_SyncPosBase function block.
-
xSyncIn
-
xSyncPosRestore
Parameters relevant for the function
The parameters are located in the L_TS2P_scPar_SyncPosBase structure.
-
scPar.lrSlaveSyncInDist , LREAL, initial value: 90 units
-
scPar.lrSlaveSyncOutDist , LREAL, initial value: 90 units
-
scPar.lrSlaveSyncOutPos , LREAL, initial value: 0
-
scPar.eSyncMode , L_TB2P_SyncMode, initial value: 0 (ProfGenAbsolute)
Example 1: Synchronous clutch-in
Synchronous clutch-in in coupling mode scPar.eSyncMode = 5 (Ramp_Dist)
|
No |
xSyncIn |
xAccDecSync |
xSynchronised |
eTMState |
Description |
|---|---|---|---|---|---|
|
A |
FALSE ä TRUE |
FALSE ä TRUE |
FALSE |
STANDBY
|
The clutch-in process is started. The axis remains at standstill until the master value is in the right position. The coupling to the master value is established and the axis accelerates until it has reached the master speed. |
|
B |
TRUE |
TRUE æ FALSE |
TRUE |
ACC_DEC_SYNC
|
The axis is synchronous with the master axis and follows the master value. |
Example 2: Asynchronous clutch-in
Asynchronous clutch-in in coupling mode scPar.eSyncMode = 5 (Ramp_Dist)
|
No |
xSyncIn |
xAccDecSync |
xSynchronised |
eTMState |
Description |
|---|---|---|---|---|---|
|
A |
FALSE ä TRUE |
FALSE ä TRUE |
FALSE |
STANDBY
|
The clutch-in process is started. The coupling to the master value is established and the axis accelerates until it has reached the master speed. |
|
B |
TRUE |
TRUE æ FALSE |
TRUE |
ACC_DEC_SYNC
|
The velocity of the axis is synchronized to the master axis and follows the master value. A position offset has built up between the master axis and the slave axis due to the asynchronous coupling. |