Position coupling
This function synchronizes the setpoint position of the drive (slave axis) to the position setpoint of the master value (master axis, scSignalflow.MP_lrSetGearboxPosOut) . The synchronization or coupling process is without a step change.
Coupling variant Path-based coupling
scPar.eSyncMode = 2 (DistAbsolute) or 3 (DistRelative)
Partial signal flow coupling for the coupling mode scPar.eSyncMode = 2 (DistAbsolute) or 3 (DistRelative)
Coupling variant Profile generator-based coupling
scPar.eSyncMode = 0 (ProfGenAbsolute) or 1 (ProfGenRelative)
This coupling type includes the "Coupling to a basic speed" function.
Partial signal flow coupling for the coupling mode scPar.eSyncMode = 0 (ProfGenAbsolute) or 1 (ProfGenRelative)