In order to be able to correct the dancer position, the circumferential speed of the winder must be faster or slower than the line. If the circumferential speed upstream of the dancer is significantly reduced in comparison to the line speed in this process, the resulting circumferential speed V Line;total for the diameter calculation should be used.
This is usually the case in applications storing larger amounts of material in the dancer mechanism.
Resulting circumferential velocity when the dancer position changes
The speed resulting from the movement of the dancer can be determined from the differentiation of the dancer position. The maximum stored material length corresponds to a change in the dancer position by 200% (from the lower standardised end position -100% to the upper standardised end position +100%).
Storage volume in the dancer
The storage volume is defined via the lrDancerMaterialLength parameter and results from twice the path between the two limit positions multiplied by the number of material loops. For non-linear dancer mechanisms (e.g. dancer arm), the storage volume should be measured as follows:
Fix the material on one side
on the other side, move the dancer with the material between the end positions
The length of material that is moved corresponds to the storage volume of the dancer.
In the case of strong non-linearity, it is recommended to linearise the dancer feedback signal using a curve module.
The dancer position is filtered via a PT1 filter with the scPar.rFiltTimeActDancerVelComp time constant.
This position is differentiated. Then the additional speed from the dancer movement is combined with the actual line speed in order to calculate the diameter lrSetLineVel .
In order that the compensation can take effect, a suitable material length must be set in scPar.lrDancerMaterialLength . With the value 0, no additional speed is generated. Therefore, no compensation takes place.
Parameters to be set
|
Identifier Data type |
Description |
|
|---|---|---|
|
lrDancerMaterialLength LREAL |
Length of the material in the dancer
|
|
|
rFiltTimeActDancerVelComp REAL |
Filter time for the speed compensation
|
|
L_TW2P_scPar_WinderDancerCtrlState
Signal flow with dancer compensation