L_TW2P_scPar_WinderDancerCtrlState

L_TW2P_scPar_WinderDancerCtrlState Basic funktions

Designator

Data type

Description

lrVel

LREAL

Speed for movements (MoveAbs, MoveRel, MoveVel) that are commissioned via the scCtrlBasicMotion structure.

  • Unit: units/s

  • Initial value: 3600

lrAcc

LREAL

Acceleration for movements (MoveAbs, MoveRel, MoveVel) that are commissioned via the scCtrlBasicMotion structure.

Specification of the maximum velocity variation which is to be used for acceleration.

  • Unit: units/s²

  • Initial value: 36000

lrDec

LREAL

Deceleration for movements (MoveAbs, MoveRel, MoveVel) that are commissioned via the scCtrlBasicMotion structure.

Specification of the maximum speed variation which is to be used for deceleration to standstill.

  • Unit: units/s²

  • Initial value: 100

lrJerk

LREAL

Jerk for movements (MoveAbs, MoveRel, MoveVel) that are commissioned via the scCtrlBasicMotion structure.

  • Unit: units/s³

  • Initial value: 0

eDirection

MC_DIRECTION

Traversing direction for movements (MoveAbs, MoveVel) that are instructed via the scCtrlBasicMotion structure:

  • mcCurrentDirection: Maintain current direction (only in case of modulo axes)

  • mcPositiveDirection: Positive direction

  • mcNegativeDirection: Negative direction

  • mcShortestWay: Shortest way (only in case of modulo axes)

  • mcPositiveCycle : Positive direction for modulo axes > cycle length

  • mcNegativeCycle : Negative direction for modulo axes > cycle length

  • Initial value: mcPositiveDirection

scHomeExtTP

MC_TRIGGER_REF

Transfer of an external touch probe event:

  • Only relevant for "external encoder" touch probe configuration.

  • For describing the MC_TRIGGER_REF structure, see the MC_TouchProbe function block.

L_TW2P_scPar_WinderDancerCtrlState technology functions

Identifier

Data type

Description

lrLineJerk

LREAL

Jerk for inching mode with the 1 / d evaluation and for the function xSyncIn

  • Unit: rev / s 3

  • Initial value: 100000

lrJogLineAcc

LREAL

Acceleration for the inching mode with the 1 / d evaluation.

Selection of the value for the maximum acceleration speed variation.

  • Unit: mm/s 2

  • Initial value: 100

lrJogLineDec

LREAL

Deceleration for the inching mode with the 1 / d evaluation.

Selection of the value for the maximum deceleration speed variation.

  • Unit: mm/s 2

  • Initial value: 10

lrJogLineVel

LREAL

Speed for the inching mode with the 1 / d evaluation.

Selection of the maximum speed used for traversing.

  • Unit: mm/s

  • Initial value: 10

lrSyncLineAcc

LREAL

Acceleration for synchronising to line velocity

  • Unit: mm/s 2

  • Initial value: 100

lrSyncLineDec

LREAL

Deceleration for synchronising to line velocity

  • Unit: mm/s 2

  • Initial value: 100

lrWebBreakWindow

LREAL

Web break window

The current diameter is compared with the maximum or minimum diameter value depending on the current winding direction. If the difference is greater than the web break window, a web break is signaled.

  • Unit: x 100 % (1.0 = 100 %)

  • Initial value: 0.1 (10 %)

lrMaxDiam

LREAL

Maximum diameter

  • Unit: mm

  • Initial value: 180

lrMinDiam

LREAL

Minimum diameter

  • Unit: mm

  • Initial value: 50

rFiltTimeDiam

REAL

PT1 filter time for the current diameter ( lrSetDiamOut )

  • Unit: s

  • Initial value: 0.05

lrDiamCalcRegularDist

LREAL

Regular calculation distance for the diameter

  • Unit: rev

  • Initial value: 1

lrDiamCalcReducedDist

LREAL

Reduced calculation distance for the diameter

  • Unit: rev

  • Initial value: 0.1

alrAdaptDiamX

ARRAY [1...9] OF LREAL

Grid points of the curve function for the diameter load value for adjustment of the analogue value to the real diameter

  • Values that may be applied to the analog input lrSetDiam .

  • Unit: mm

  • Initial values: 0, 100, 200, 300, 400, 500, 600, 700, 800

alrAdaptDiamY

ARRAY [1...9] OF LREAL

Grid points of the curve function for the diameter load value for adjustment of the analogue value to the real diameter

  • Function values for the diameter

  • Unit: mm

  • Initial values: 0, 100, 200, 300, 400, 500, 600, 700, 800

lrTensCurveCtrlScaled

LREAL

Gradient of the characteristic for the tension control open loop

  • Unit: x 100 % (1 = 100 %)

  • Initial value: 0

  • The value '1' causes a constant tensile force profile and thus a proportionally increasing setpoint for the diameter.

lrTensCurveStartDiamScaled

LREAL

Initial point of the characteristic for the tension control open loop

  • Unit: x 100 %

  • 1 = 100 % = lrMaxDiam parameter

  • Initial value: 0 (0 %)

lrLineVelRef

LREAL

Maximum line velocity

  • Unit: mm/s

  • Initial value: 1000

lrMinLineVel

LREAL

Minimum line velocity

Up to this velocity, the diameter is held .

  • Unit: mm/s

  • Initial value: 1

rFiltTimeMaterialCounter

REAL

Filter time constant for the material length counter ( lrMaterialCounter output)

    Initial value: 0 (filter is deactivated.)

lrSetMaterialPos

LREAL

Position of the material length counter

With a FALSE ä TRUE edge at the xSetMaterialCounter input, the material length counter ( lrMaterialCounter output) is set to the value in lrSetMaterialPos .

  • Unit: mm

  • Initial value: 0

lrMaxWndSpd

LREAL

Definition of the maximum winder shaft speed (at the output end). Unit: rev / s

Initial value: 100

lrHystlineStandstill

LREAL

Hysteresis width for stabilising a noisy line speed including direction detection

The value to be set is the maximum noise amplitude detected

  • Unit: mm/s

  • Initial value: 0

eDiamCalcValueSource

MC_SOURCE

Source for the speed of the axis used to calculate the diameter.

mcSetValue

Set values are used

mcActualValue

Actual values of the feedback system are used

xLineVelDiamCalc

BOOL

Diameter calculation

  • Initial value: FALSE

TRUE

For calculating the diameter, the velocity from the lrSetLineVelDiamCalc input is used.

FALSE

For calculating the diameter, the velocity from the lrSetLineVel input is used.

lrTargetMaterialCounter

LREAL

The material length counter on the winder, which must be reached. Depending on the winding direction (winding / unwinding), the material length counter is counted up or down.

  • Unit: mm

Configuration: "eDancerCtrlMode = 2" AND "eDancerCtrlStopMode = 4":

The deceleration phase is initiated. The winder is brought to a standstill via lrSyncLineDec and lrLineJerk.

When the braking process starts, the status xLineStop = TRUE is set so that the counter reading lrTargetMaterialCounter is not exceeded.

The profile parameters lrSyncLineDec and lrLineJerk are used to calculate the status.

lrDancerPosRamp

LREAL

Acceleration ramp for dancer position setpoints

  • Unit: 1 / s

  • Initial value: 1

lrDancerPosCtrlGain

LREAL

Controller gain

  • Initial value: 1

lrDancerPosCtrlResetTime

LREAL

Controller reset time

  • Unit: s

  • Initial value: 0 controller reset time is deactivated.)

eResetICtrlMode

L_TW2P_ResetICtrlMode

Mode for setting the function for resetting the correcting variable from the I component via the xResetICtrl input = TRUE

    Initial value: 1

0

Instant

With a rising edge xResetICtrl = TRUE, the correcting variable from the I component is set to 0 immediately (abruptly).

1

Ramp

With a rising edge xResetICtrl = TRUE, the correcting variable from the I component is ramped to zero via the scPar.IrDancerPosCtrlResetTime parameter.

lrDancerPosCtrlLimPos

LREAL

Limitation of the dancer position controller correcting variable (output of the controller) in positive direction

  • Initial value: 1

lrDancerPosCtrlLimNeg

LREAL

Limitation of the dancer position controller correcting variable (output of the controller) in negative direction

  • Initial value: -1

lrDancerMaxPosScaled

LREAL

Maximum dancer position for the xDancerMaxPos status bit

  • Unit: x 100 % (1 = 100 %)

  • Initial value: 0.95 (95 %)

lrDancerMinPosScaled

LREAL

Minimum dancer position for the xDancerMaxPos status bit

  • Unit: x 100 % (1 = 100 %)

  • Initial value: -0.95 (-95 %)

xTeachDancerLimits

BOOL

Source of the dancer position limitations

  • Initial value: FALSE

TRUE

The limit positions lrDancerLowerLimit and lrDancerUpperLimit are used until the teaching function has been executed. After the teaching function has been executed manually, the saved limit positions from the teaching function are always used.

FALSE

The limit positions lrDancerLowerLimit and lrDancerUpperLimit are used.

lrDancerUpperLimit

LREAL

Analog value for the upper dancer position limit

  • Initial value: 10 000 000

lrDancerLowerLimit

LREAL

Analog value for the lower dancer position limit

  • Initial value: 0

lrDancerMaterialLength

LREAL

Length of the material in the dancer

  • Unit: mm

  • Initial value: 0

  • The value 0 is used to deactivate examination of the dancer movement.

lrDancerInPosWindowScaled

LREAL

Window for the set position of the dancer to control the xDancerReachedSetPos status bit.

  • Unit: x 100 % (1.0 = 100 %)

  • Initial value: 0.2 (20 %)

rFiltTimeActDancerPosIn

REAL

PT1 filter time for the lrActDancerPosIn input

  • Unit: s

  • Initial value: 0.005

rFiltTimeActDancerVelComp

REAL

Filter time for the speed compensation

  • Unit: s

  • Initial value: 0

wWebBreakMode

WORD

Mode for web break monitoring

  • Initial value: 1

0

Web break monitoring via diameter calculation and dancer position

1

Web break monitoring only via the dancer position

2

Web break monitoring only via diameter calculation

dwSelectTensCurve

DWORD

Selection of the characteristic for tension control

  • Initial value: 0

0

Linear tensile force profile

1

Linear torque profile

2

Tensile force profile on the basis of a specified characteristic

alrTensCurve

ARRAY [1...65] OF LREAL

Characteristic for the tension control open loop (consisting of 65 values)

All 65 values must be evenly distributed over the diameter range of the parameters lrMinDiam and lrMaxDiam (minimum and maximum diameter).

  • Unit: scaled value between 0 and 1

The first array value (index 1) represents the diameter lrTensCurveStartDiamSvaled

The last array value (index 65) represents the diameter lrMaxDima

rFiltTimeAccSpd

REAL

PT1 filter time for the winder shaft speed for acceleration compensation

  • Unit: s

  • Initial value: 0.005

lrAccCmpsDeadBandTrq
Scaled

LREAL

Lagging range ( Dead band ) for the current acceleration torque

  • Unit: x 100 % (1.00 = 100 %);
    reference variable: rated motor torque [Nm]

  • Initial value: 0.1 (10 %)

lrAccCmpsGainAcc

LREAL

Gain factor for the acceleration torque in positive direction

  • Unit: x 100 % (1.00 = 100 %)

  • Value range: 0 ... 2 (0 ... 200%)

  • Initial value: 1.05 (105 %)

lrAccCmpsGainDec

LREAL

Gain factor for the acceleration torque in negative direction

  • Unit: x 100 % (1.00 = 100 %)

  • Value range: 0 ... 2 (0 ... 200%)

  • Initial value: 0.95 (95 %)

lrConstMInertia

LREAL

Constant moment of inertia at the winder shaft

  • Unit: kgcm 2

  • Initial value: 1

lrMaxMInertia

LREAL

Maximally permissible moment of inertia at the winder shaft

  • Unit: kgcm 2

  • Initial value: 10

rFiltTimeIdentMInertiaSpd

REAL

PT1 filter time for the speed at the winder shaft during the identification of the moment of inertia

  • Unit: s

  • Initial value: 0.01

rFiltTimeIdentMInertiaTrq

REAL

PT1 filter time for the torque at the winder shaft during the identification of the moment of inertia

  • Unit: s

  • Initial value: 0.005

lrIdentMInertiaMaxSpd
Scaled

LREAL

Maximum speed of the winder shaft during the identification of the moment of inertia

  • Unit: x 100 % (1.0 = 100 % = lrWndSpdRef )

  • Value range: 0 ... 1 (0 ... 100 %)

  • Initial value: 0.2 (20 %)

lrIdentMInertiaMaxTrq
Scaled

LREAL

Maximum torque of the winder shaft during the identification of the moment of inertia

  • Unit: x 100 % (1.0 = 100 %)
    reference variable: rated motor torque

  • Value range: 0 ... 1 (0 ... 100 %)

  • Initial value: 0.2 (20 %)

eAdaptSpdCtrlGainMode

L_TW2P_AdaptSpdCtrlGainMode

Mode selection for adaptation of the speed controller gain.

    Initial value: 2

0

DiamToSquare; VP = f(d 2 )

1

Diam; VP = f(d)

2

Inertia; VP = f(J)

lrAdaptSpdCtrlLowLimit

LREAL

Lower limitation of speed controller gain in the drive.

The lrSetSpdCtrlGainAdaptOut adaptation value must not be smaller than the scPar value. lrAdaptSpdCtrlLowLimit .

  • Value range: 0 to 1

  • Initial value: 0.2 (20 %)

alrSpdCtrlGainAdaptX

ARRAY [1...9] OF LREAL

Characteristic function for the speed control gain

The X axis corresponds to the adaption factor currently calculated for the adaptation of the speed controller gain.

  • Unit: x 100 % (1 = 100 % = lrMaxMInertia parameter)

  • Initial values: [0.0, 0.2, 0.4, 0.6, 0.8, 1.0, 1.2, 1.4, 1.6]

alrSpdCtrlGainAdaptY

ARRAY [1...9] OF LREAL

Characteristic function for the speed control gain

The Y axis corresponds to the gain factor of the speed controller.

  • Unit: x 100 % (1 = 100 %)

  • Initial values:

  • Initial values: [0.0, 0.2, 0.4, 0.6, 0.8, 1.0, 1.2, 1.4, 1.6]

lrReducedGainWindow

LREAL

Area of the system deviation with a reduced gain / sensitivity.

With lrReducedGainWindow , the tolerance zone of the system deviation is defined, in which lrReducedGain takes effect.

  • Initial value: 0.0

lrReducedGain

LREAL

Gain of system deviation within the reduced sensitivity

  • Initial value: 0.0

eDancerCtrlStopMode

L_TW2P_DancerCtrlStopMode

Mode in which the winding process ("DANCERCTRL" state) is stopped.

  • Initial value: 0

0

Holding

The axis is stopped via the deceleration ( lrHaltDec ) and the jerk ( lrJerk ).

1

Move ABS

Absolute travel/positioning:

The axis travels to the target position ( lrPos_Dist ) with the velocity ( lrVel ), acceleration ( lrAcc ), deceleration ( lrDec ) and the jerk ( lrJerk ).

2

Move Rel

Relative travel/positioning:

The axis is brought to a standstill with the velocity ( lrVel ), acceleration ( lrAcc ), deceleration ( lrDec ) and the jerk ( lrJerk ) after the distance travelled ( lrPos_Dist ).

3

MoveAbsShortestWay

Absolute travel/positioning:

The axis is moved to the target position ( lrPos_Dist ) using the shortest path with the velocity ( lrVel ), acceleration ( lrAcc ), deceleration ( lrDec ) and the jerk ( lrJerk ).

4

StopVelocityMaster

Stop via landing calculator. The winder is brought to a standstill so that the material length calculator lrMaterialCounter reaches the predefined target value lrTargetMaterialCounter.

The profile parameters lrSyncLineDec and lrLineJerk are used for the deceleration.

Note: This only applies to operating mode eDancerCtrlMode = 2 (VelocityMaster). Otherwise a warning is signalled (eErrorID = InvalidStopMode)

eDancerCtrlMode

L_TW2P_WinderDancerControlMode

Selection of the type of control of the axle for the winding

The mode is effective in winding mode when the dancer control is activated.

  • Initial value: 1 (SpeedBased)

1: SpeedBased

Normal winding operation with the dancers' closed loop control system

Speed control is activated in the drive when the technology module changes to the "DANCERCTRL" state.

2: VelocityMaster

The winder is set in VelocityMaster mode. This makes the winder a velocity master drive for the following winder modules.

The set value from the "VelocityMaster" is interpolated and provided as the resulting line speed at the lrSetlineVelOut output.

lrIdentDiamVel

LREAL

Circumferential speed of the winding shaft for identification of the diameter.

  • Unit: mm/s

  • Initial value: 10

lrIdentDiamAcc

LREAL

Circumferential acceleration of the winding shaft for identification of the diameter.

  • Unit: mm/s 2

  • Initial value: 100

lrIdentDiamDec

LREAL

Circumferential deceleration of the winding shaft for identification of the diameter.

  • Unit: mm/s 2

  • Initial value: 100

lrIdentDiamJerk

LREAL

Circumferential jerk of the winding shaft for identification of the diameter.

  • Unit: mm/s 3

  • Initial value: 0

wIdentDiamCalcCycles

WORD

Number of calculation cycles for successful identification

  • Initial value: 2

lrIdentDiamMaxDancerPos

LREAL

Scaled end position of the dancer during identification. The identification run is aborted if the end position is exceeded.

Setting range: -1 ... 1

Initial value: 0.5

lrIdentDiamSpdCtrlGain

LREAL

The speed controller gain is set when the speed controller gain xAdaptSpdCtrlGain = TRUE during diameter identification.

Setting range: 0 ... 1

Initial value: 0.5

IrHystlineStandstill

LREAL

Hysteresis width for the line speed

This stabilises the noisy line speed and the direction recognition. After detecting the maximum noise amplitude of the input signal, set this value.

Unit: mm/s

Initial value: 0