Inputs

Basic functions

Designator

Data type

Description

xEnable

BOOL

TRUE

The function block is activated.

FALSE

The function block is deactivated.

xEnableOperation

BOOL

TRUE

The axis is switched to the "ready for operation" state.

Controller enable is issued.

xResetError

BOOL

FALSEäTRUE

Reset axis error or software error.

xQSPApplication

BOOL

TRUE

The axis is brought to a standstill with speed control and/or held there with position control using the parameters of the QSP application.

  • The technology module remains in the "STOP" state as long as the quick stop is executed.

  • The function cannot be replaced by another function.

xAbort

BOOL

FALSEäTRUE

The active movement is cancelled and the axis is brought to a standstill profile deceleration (scPar.IrDec).

  • The state changes to "Stop".

The deceleration ramp can be aborted by commissioning of a new movement (e.g. xMoveVelExecute)

xJogPos

BOOL

TRUE

Traverse axis in positive direction (manual jog).

If xJogNeg is also TRUE, the eErrorID output displays the "InvalidInputJogPosJogNeg" error message and the axis stops.

xJogNeg

BOOL

TRUE

Traverse axis in negative direction (manual jog).

If xJogPos is also TRUE, the eErrorID output displays the "InvalidInputJogPosJogNeg" error message and the axis stops.

xHomeExecute

BOOL

FALSEäTRUE

Start homing.

The function is aborted via the xHalt input.

lrOverride

LREAL

With the lrOverride factor, the defined setpoint speed is multiplied (e.g. an override value of 0.5 generates half the setpoint speed)

  • Value range: 0 ... 1.0

  • Initial value: 1.0

Note: Acceptance of the value is carried out irrespective of the status in xContinuousUpdate.

scCtrlBasicMotion

L_TB2P_scCtrlBasicMotion

Structure input for controlling basic motion functions

Technology functions

Identifier

Data type

Description

scPar

L_TW2P_scPar_WinderDancerCtrlState

Parameters of the technology module summarised in a structure.

Axis

AXIS_REF

Reference to the axis

scAccessPoints

L_TW2P_scAP_WinderDancerCtrlState

Access points that are summarised in a structure and can be used to influence the signal flow or the functions of the technology module.

PersistentVar

L_TW2P_PersistentVarWinder

Content of the persistent variables within the L_TW2P_PersistentVarWinder structure

xMaterialFeeding

BOOL

Material feeding at the reels from the top or from the bottom

  • Initial value: FALSE

WARNING!

Injury to persons

Risk of injury is caused by changing the setting at the xMaterialFeeding input during a movement. This can lead to a speed jump of the winder axis.

Possible consequences

Death or severe injuries

Protective measures

Only change the setting of the xMaterialFeeding input if the technology module is not running and the inverter is disabled:

  • xEnable input = FALSE

  • xEnableOperation input = FALSE

TRUE

Material feeding from the top

FALSE

Material feeding from the bottom

xWindingDirection

BOOL

Function of the winder for positive line speed ( lrSetLineVel > 0)

  • Initial value: FALSE

WARNING!

Injury to persons

Risk of injury is caused by changing the setting at xWindingDirection input during a movement. This can lead to a speed jump of the winder axis.

Possible consequences

Death or severe injuries

Protective measures

Only change the setting of input xWindingDirection if the technology module is not running and the inverter is disabled:

  • xEnable input = FALSE

  • xEnableOperation input = FALSE

TRUE

Unwinder

FALSE

Rewinder

xJogLinePos

BOOL

TRUE

Drive axis in positive material flow direction (manual jog).

The path parameters (speed, acceleration and deceleration) refer to the circumferential speed of the reel.

ATTENTION: xJogLinePos has a higher priority than xDanceCtrl. This will interrupt an active winding process!

xJogLineNeg

BOOL

TRUE

Drive axis in negative material flow direction (manual jog).

The path parameters (speed, acceleration and deceleration) refer to the circumferential speed of the reel.

ATTENTION: xJogLineNeg has a higher priority than xDanceCtrl. This will interrupt an active winding process!

lrSetLineVel

LREAL

Current line velocity

  • Unit: mm/s

lrSetLineVelDiamCalc

LREAL

Current line speed for diameter calculation.

  • Used when scPar. xLineVelDiamCalc = TRUE is set.

  • Unit: mm/s

xLoadDiam

BOOL

TRUE

Load the (start) diameter from the lrLoadDiam input.

  • Initial value: FALSE

lrLoadDiam

LREAL

Defining a (start) diameter

The diameter is loaded cyclically when the xLoadDiam is set to TRUE.

  • Unit: mm

  • Initial value: 0

xHoldDiam

BOOL

Hold the current diameter

Initial value: FALSE

TRUE

Current diameter is held.

FALSE

The current diameter is not held.

xDiamCalcReduced

BOOL

Mode change-over of the diameter calculation between a long/short distance

  • Initial value: FALSE

TRUE

Diameter is updated after the short distance.

FALSE

Diameter is updated after the long distance.

xWebBreakMonit

BOOL

Activate/Deactivate web break monitoring

  • Initial value: FALSE

TRUE

Activate web break monitoring.

FALSE

Deactivate web break monitoring.

xSyncIn

BOOL

Synchronising the winder axis to the line speed lrSetLineVel

(commissioning function to make the winder follow the line speed without material).

The input is level-controlled and evaluates a HIGH level.

The axis must be enabled via xEnableOperation (the TM state is then set to eTMState = SYNCLINEVEL).

By setting xDancerCtrl = TRUE, it is then possible to switch directly to winding mode (eTMState = DANCERCTRL)

TRUE

Synchronise winder axis to velocity of lrSetLineVel

(Synchronisation uses accelerating value from lrSyncLineAcc)

FALSE

No synchronisation of winder axis to velocity of lrSetLineVel

(Stopping using the deceleration value lrSyncLineDec)

xTeachUpperPos

BOOL

TRUE

The current dancer position is stored as the upper limit value.

xTeachLowerPos

BOOL

TRUE

The current dancer position is stored as the lower limit value.

lrActDancerPosIn

LREAL

Current dancer position

The actual dancer position can be fed back to the controller, e.g. in the form of an analogue signal (0 ... 10 V). The scaling is done via the parameters lrDancerUpperLimit and lrDancerLowerLimit or via the teach function.

xDancerCtrl

BOOL

TRUE

Activate dancer position control.

TRUE æ FALSE

Dancer position control is deactivated.

With the scPar.eDancerCtrlStopMode defined, the winding process is stopped.

lrSetDancerPosScaled

LREAL

Scaled setpoint for the dancer position

  • Unit: x 100 %

  • Initial value: 0

  • Value range: -1 ... 1 (-100 ... 100 %)

IrCtrlDancerPosInfluenceScaled

LREAL

Influence range of the dancer position controller

  • Unit: x 100 %

  • Initial value: 0

  • Value range: 0 ... 1 (0 ... 100 %)

xResetICtrl

BOOL

TRUE

The I component of the PI controller can be switched off and the correcting variable (output of the controller) from the I component can be led to the value 0 via the ramp function. The correcting variable from the P component is not affected.

xAccCmps

BOOL

Activate/Deactivate acceleration compensation during the dancer position control

  • Initial value: FALSE

lrMInertiaAdapt

LREAL

Multiplier for the current moment of inertia

  • Initial value: 1

xExecuteIdentMInertia

BOOL

FALSE ä

TRUE

The moment of inertia at the winder shaft is detected.

The lrIdentMInertia output displays the detected moment of inertia in kgcm 2 .

xExecuteIdentDiam

BOOL

FALSE ä

TRUE

Identification of the diameter is started.

The dancer is lifted while the line speed is zero. By means of the dancer lift, the reel diameter is calculated from the data determined, which refer to the material length covered and the angle of rotation.

xAdaptSpdCtrlGain

BOOL

Switch adaptation of the speed controller gain on/off.

  • Initial value: FALSE

TRUE

Enable adaptation of the speed controller gain.

FALSE

Adaptation of the speed controller gain inactive.

lrAdaptSpdCtrlGainFactor

LREAL

The resulting value of the adaptation of the speed controller gain can be influenced multiplicatively via this input.

  • Value range: 0 ... 1

  • Initial value: 1

xTensCurve

BOOL

Enable tensile force characteristic

Initial value: FALSE

TRUE

Enable tensile force characteristic.

FALSE

Lock tensile force characteristic.

lrSetTens

LREAL

Tensile force setpoint

  • Unit: N

  • Initial value: 0

xSetMaterialCounter

BOOL

FALSE ä

TRUE

Sets the material length counter ( lrMaterialCounter output) to the value set under the lrSetMaterialPos parameter.

MaterialCounterValues

L_MC1P_IAXIS_REF_MASTERVALUES

Here a modulo axis of a measuring wheel can be connected to the material.

If an axis is connected to the input, the material length is determined on the basis of the data from the reference axis. This procedure is also suitable for noisy signals.

If no axis is connected here, the material length is determined from the integration of the material speed ( lrSetLineVel or lrSetLineVelDiamCalc input).

  • Material length counter

  • Sources for the material length counting

Supported axes:

  • Encoder

  • 9400 HighLine servo inverter

  • i700 servo inverter

  • i950 servo inverter