Outputs

Basic functions

Designator

Data type

Description

xReadyForOperation

BOOL

The axis is faultless.

The DC bus voltage is available.

"Safe Torque Off" (STO) is not active.

xOperationEnabled

BOOL

The axis is enabled.

The brake is released.

xReadyForMotion

BOOL

The axis is enabled and faultless.

The brake is released.

xError

BOOL

TRUE

There is an error in the technology module.

xWarning

BOOL

TRUE

There is a warning in the technology module.

eErrorID

L_IE1P_Error

ID of the error or warning message if xError = TRUE or xWarning = TRUE.

Here you can find information on error and warning messages: L_IE1P_Error

xSTOActive

BOOL

TRUE

"Safe Torque Off" (STO) was enabled and is active.

The axis is torque-free and the inverter is inhibited.

xQSPActive

BOOL

TRUE

The xQSPApplication input is set to TRUE.

The technology module is in the "STOP" state, the axis is brought to a standstill.

The output is reset as soon as the axis is at a standstill.

xAbortBusy

BOOL

TRUE

The function activated is aborted by the xAbort input.

xAbortDone

BOOL

TRUE

The activated function is aborted by the xAbort input.

xJoggingBusy

BOOL

TRUE

The manual jog function is active.

The technology module is in the "JOGGING" state.

xHomingBusy

BOOL

TRUE

Homing is executed.

The technology module is in the "HOMING" state.

xHomingDone

BOOL

TRUE

Homing has been completed successfully.

xIsHomed

BOOL

TRUE

The axis has been referenced ("Reference known").

xIsHomed may only be evaluated when the xAxisAvailable status is reported.

eTMState

L_TB2P_States

Current state of the technology module

scStatusBasicMotion

L_TB2P_scStatusBasicMotion

Structure of the status data of the function block

lrActVel

LREAL

Current velocity

  • Unit: units/s

lrSetVelOut

LREAL

Setpoint speed

  • Unit: units/s

lrActPos

LREAL

Actual position

  • Unit: units

lrSetPosOut

LREAL

Setpoint position

  • Unit: units

lrActFollowingError

LREAL

Current following error

  • Unit: units

Technology functions

Identifier

Data type

Description

scSignalFlow

L_TW2P_scSF_WinderDancerCtrlState

Structure of the signal flow

xHoldDiamActive

BOOL

Status of the diameter calculation.

Note: When this output is toggled, we recommend that the hysteresis function is used ( scPar.lrHystlineStandstill parameter).

  • Signal flow diagram

TRUE

Current diameter is held.

FALSE

The current diameter is updated.

xDiamMax

BOOL

TRUE

The maximum diameter has been reached.

xDiamMin

BOOL

TRUE

The minimum diameter has been reached.

lrSetDiamOut

LREAL

Current diameter calculated

  • Unit: mm

xWebBreak

BOOL

TRUE

A web break has occurred.

xSynchronised

BOOL

TRUE

The winder is synchronised with the line speed.

xAccDecSync

BOOL

TRUE

The synchronisation function is active.

Synchronisation of the winder is carried out or cancelled.

xWindingBusy

BOOL

TRUE

Winding operation has been activated.

xUnwind

BOOL

Status bit for unwinder and rewinder

Note: When this output is toggled, we recommend that the hysteresis function is used ( scPar.lrHystlineStandstill parameter).

  • Signal flow diagram

TRUE

Unwinder

FALSE

Rewinder

lrActDancerPosScaled

LREAL

Current scaled dancer position

  • Unit: x 100 %

  • Value range: -1 ... 1 (-100 ... 100 %)

xDancerReachedSetPos

BOOL

TRUE

The dancer has reached the setpoint position and is within the scPar.lrDancerInPosWindowScaled tolerance window.

xDancerMaxPos

BOOL

TRUE

The dancer has reached the upper limit position.

xDancerMinPos

BOOL

TRUE

The dancer has reached the lower limit position.

lrSetMInertiaOut

LREAL

Current moment of inertia at the winder shaft

  • Unit: kgcm 2

xIdentBusy

BOOL

TRUE

The identification of the mass inertia or the friction is determined.

xIdentDone

BOOL

TRUE

The identification of the mass inertia or the friction has been completed.

lrIdentMInertia

LREAL

Identified moment of inertia at the winder shaft

  • Unit: kgcm 2

lrSetSpdCtrlGainAdaptOut

LREAL

Adaptation of the speed controller gain

  • Unit: x 100 % (1 = 100 %)

lrSetTensCurveOut

LREAL

Current tensile force setpoint from the curve function

lrMaterialCounter

LREAL

Display of the material length counter content on the winder

Depending on the definition of the winding direction, the material length counter is incremented or decremented

  • Unit: mm

  • Defining the winding direction (winding/unwinding)

lrLimitLineVel

LREAL

The maximum permitted line speed is determined from the calculated diameter and the scPar. lrMaxWndSpd parameter.

  • Unit [mm/s]

xVelocityMasterBusy

BOOL

TRUE

The "velocity Master" mode is activated.

FALSE

The "velocity Master" mode is deactivated.

Normal winding mode is activated.

lrSetLineVelOut

LREAL

In "VelocityMaster" mode (eDancerCtrlMode = 2), this is the line speed which serves as the reference value for all subsequent winding modules.

In "SpeedBased" mode (eDancerCtrlMode = 1), the line speed is passed through

(lrSetLineVelOut = lrSetLineVel)

  • Unit: mm/s

xLineStop

BOOL

TRUE

In VelocityMaster mode (eDancerCtrlMode = 2):

The deceleration of the line speed is active. The line speed at output lrSetLineVelOut is brought to a standstill by the profile parameters lrSyncDec and lrLineJerk.

In "SpeedBased" mode (eDancerCtrlMode = 1) :

The VelocityMaster stops when the value of the material counter scPar.lrTargetMaterialCounter is reached.