L_TW2P_scSF_WinderDancerCtrlState
Structure of the signal flow
The content of the structure is read-only and offers a practical diagnostics option within the signal flow.
Signal flow diagram
|
Identifier Data type |
Description |
|
|---|---|---|
|
MP_lrWndVelRef LREAL |
Rated velocity of the reel (output end)
|
|
|
MP_lrWndSpeedRef LREAL |
Rated speed of the reel (output end)
|
|
|
MP_liRevCounter LREAL |
Counter content of the material length counter (whole numbers of complete reel revolutions; only active when an axis is connected to the MaterialCounterValues input) |
|
|
MP_lrRevCounterResidual LREAL |
Counter content of the material length counter (residual value after one complete reel revolution; only active when an axis is connected to the MaterialCounterValues input)
|
|
|
MP_lrAxisSpeed LREAL |
Current speed of the reel (output end)
|
|
|
MP_xDiamCalculated LREAL |
FALSE รค TRUE edge: The diameter has been calculated. The measuring point is only set to TRUE for one PLC cycle. |
|
|
MP_lrSetDiamUnfiltered LREAL |
Current diameter calculated
|
|
|
MP_lrSetDiamAdapted LREAL |
Diameter resulting from the lrSetDiam input.
|
|
|
MP_lrSetDiamScaledOut LREAL |
Scaled diameter resulting from the lrSetDiam input.
|
|
|
MP_lrSetLineVelScaledOut LREAL |
Scaled line speed
|
|
|
MP_lrActTotalTrqScaled LREAL |
Torque calculated from the measured current (scaled)
|
|
|
MP_lrSetSpeedPoint LREAL |
Resulting speed setpoint
|
|
|
MP_lrDancerPosScaled0To1 LREAL |
Scaled dancer position
|
|
|
MP_lrDancerCompVelOut LREAL |
Resulting speed of the dancer
|
|
|
MP_lrFiltDancerCompVelOut LREAL |
Filtered resulting speed of the dancer
|
|
|
MP_lrFiltActDancerPos
LREAL |
Actual scaled filtered dancer position
|
|
|
MP_lrSetRampDancerPos LREAL |
Target position of the dancer after the ramp generator This position is the reference variable of the winding drive.
|
|
|
MP_lrDancerCtrlPosOut LREAL |
Correcting variable of the dancer position controller
|
|
|
MP_lrDancerCtrlLineVelOut LREAL |
Correcting variable of the dancer position controller converted to the line speed
|
|
|
MP_lrDancerCtrlOutGain LREAL |
Scaled correcting variable from the proportional component (P-component) of the dancer position controller |
|
|
MP_lrDancerCtrlOutReset
LREAL |
Scaled correcting variable from the integrating component (I-component) of the dancer position controller |
|
|
MP_lrDancerCtrlOutRate
LREAL |
Scaled correcting variable from the differentiating portion (D portion) of the dancer position controller |
|
|
MP_lrDancerCtrlScaledOut LREAL |
Scaled correcting variable of the dancer position controller
|
|
|
MP_lrAxisTorque LREAL |
Torque pre-control value of the reel (output end)
|
|
|
MP_lrSetTrqPoint LREAL |
Torque pre-control value of the reel (output end)
|
|
|
MP_xLineStandStill BOOL |
TRUE |
Standstill of the line has been detected. |
|
MP_xInternalControlActive BOOL |
The technology module is currently controlled by the InternalControl functionality (visualization template). Commands from the tm interface are ignored. |
|