L_TW2P_scSF_WinderDancerCtrlState

Structure of the signal flow

The content of the structure is read-only and offers a practical diagnostics option within the signal flow.

Signal flow diagram

Identifier

Data type

Description

MP_lrWndVelRef

LREAL

Rated velocity of the reel (output end)

  • Unit: units/s

MP_lrWndSpeedRef

LREAL

Rated speed of the reel (output end)

  • Unit: rev/s

MP_liRevCounter

LREAL

Counter content of the material length counter (whole numbers of complete reel revolutions; only active when an axis is connected to the MaterialCounterValues input)

MP_lrRevCounterResidual

LREAL

Counter content of the material length counter (residual value after one complete reel revolution; only active when an axis is connected to the MaterialCounterValues input)

  • Unit: 1 x 100 %

  • 100 % = One reel revolution

MP_lrAxisSpeed

LREAL

Current speed of the reel (output end)

  • Unit: rev/s

MP_xDiamCalculated

LREAL

FALSE รค TRUE edge: The diameter has been calculated. The measuring point is only set to TRUE for one PLC cycle.

MP_lrSetDiamUnfiltered

LREAL

Current diameter calculated

  • Unit: mm

MP_lrSetDiamAdapted

LREAL

Diameter resulting from the lrSetDiam input.

  • Unit: mm

MP_lrSetDiamScaledOut

LREAL

Scaled diameter resulting from the lrSetDiam input.

  • Unit: 1x100%

  • 100% lrMaxDiam

MP_lrSetLineVelScaledOut

LREAL

Scaled line speed

  • Unit 1 x 100%

  • 100% lrLineVelRef

MP_lrActTotalTrqScaled

LREAL

Torque calculated from the measured current (scaled)

  • Unit x100%

  • 100% nominal torque

MP_lrSetSpeedPoint

LREAL

Resulting speed setpoint

  • Unit: rev/s

MP_lrDancerPosScaled0To1

LREAL

Scaled dancer position

  • Unit: 1 x 100 %

  • Value range: -1 ... 1 (-100 ... 100 %)

  • -100 % = lower dancer end position

  • 100 % = upper dancer end position

MP_lrDancerCompVelOut

LREAL

Resulting speed of the dancer

  • Unit: 1 x 100 %/s

MP_lrFiltDancerCompVelOut

LREAL

Filtered resulting speed of the dancer

  • Unit: 1 x 100 %/s

MP_lrFiltActDancerPos
Scaled

LREAL

Actual scaled filtered dancer position

  • Unit: 1 x 100 %

  • Value range: -1 ... 1 (-100 ... 100 %)

MP_lrSetRampDancerPos

LREAL

Target position of the dancer after the ramp generator

This position is the reference variable of the winding drive.

  • Unit: 1 x 100 %

  • Value range: -1 ... 1 (-100 ... 100 %)

MP_lrDancerCtrlPosOut

LREAL

Correcting variable of the dancer position controller

  • Unit: 1 x 100 %

  • Value range: -1 ... 1 (-100 ... 100 %)

MP_lrDancerCtrlLineVelOut

LREAL

Correcting variable of the dancer position controller converted to the line speed

  • Unit: mm/s

MP_lrDancerCtrlOutGain

LREAL

Scaled correcting variable from the proportional component (P-component) of the dancer position controller

MP_lrDancerCtrlOutReset
Time

LREAL

Scaled correcting variable from the integrating component (I-component) of the dancer position controller

MP_lrDancerCtrlOutRate
Time

LREAL

Scaled correcting variable from the differentiating portion (D portion) of the dancer position controller

MP_lrDancerCtrlScaledOut

LREAL

Scaled correcting variable of the dancer position controller

  • Unit: 1 x 100 %

  • Value range: -1 ... 1 (-100 ... 100 %)

MP_lrAxisTorque

LREAL

Torque pre-control value of the reel (output end)

  • Unit: Nm

MP_lrSetTrqPoint

LREAL

Torque pre-control value of the reel (output end)

  • Unit: Nm

MP_xLineStandStill

BOOL

TRUE

Standstill of the line has been detected.

MP_xInternalControlActive

BOOL

The technology module is currently controlled by the InternalControl functionality (visualization template). Commands from the tm interface are ignored.