L_TW2P_scAP_WinderDancerCtrlState

Structure of the access points

The access points (AP) can be used to influence signals. In the initial state, the access points do not have any effect.

Each access point acts as an alternative branch and is activated via an OR operation or a switch.

Identifier

Data type

Description

AP_xSetVelOffset

BOOL

Release of the access point AP_lrVelOffset

TRUE

The access point overwrites the values at the access point in the signal flow.

AP_lrVelOffset

LREAL

Cyclic specification of the offset for the velocity of the winder axis with regard to the winding shaft (gearbox output side)

  • Unit: units/s

The offset value is set immediately and abruptly without ramp generator!

AP_xSetTrqOffset

BOOL

Enable of the AP10_lrSetTrqOffset access point

TRUE

The access point overwrites the values at the access point in the signal flow.

AP_lrSetTrqOffset

LREAL

Cyclic specification of the offset for the torque of the winder axis with regard to the winding shaft (gearbox output side)

  • Unit: Nm

The offset value is set immediately and abruptly without ramp generator!

AP_xSetVelOffsetDiam
Calc

BOOL

Enable of the access point AP11_lrSetVelOffsetDiamCalc:

TRUE

The access point overwrites the values at the access point in the signal flow

AP_lrVelOffsetDiamCalc

LREAL

Cyclic presetting of the offset for the speed of the winder axis in relation to the winding shaft (gear output side) for the calculation of the diameter.

  • Unit: units/s

The offset value is set immediately and abruptly without a ramp generator!

AP_xSetSpeedPointDiam
Calc

BOOL

Release of the access point AP_lrSetSpeedPointDiamCalc

TRUE

The access point overwrites the values at the access point in the signal flow.

AP_lrSetSpeedPointDiam

Calc

LREAL

Cyclic selection of the speed of the winder axis used for calculating the diameter.

This access point has no effect on the setpoint of the winder axis but is included in the calculation of the diameter.

AP_xSetSpeedPoint

BOOL

Enable of the AP01_lrSetSpeedPoint access point

TRUE

The access point overwrites the values at the access point in the signal flow.

AP_lrSetSpeedPoint

LREAL

Speed setpoint for the winding drive

  • Unit: unit/s

Note: If the setpoint is specified in the unit [rev/s], the feed constant must be taken into account

AP_xSetTrqPoint

BOOL

Enable of the AP02_lrSetTrqPoint access point

TRUE

The access point overwrites the values at the access point in the signal flow.

AP_lrSetTrqPoint

LREAL

Torque setpoint for the feedforward control

  • Unit: Nm

AP_xDisableInternalControl

BOOL

TRUE

Disable the InternalControl functionality of the technology module. If TRUE, the technology module cannot be controlled by the visualization template.