Continuous travel with a defined velocity

Prerequisite

  • The axis is enabled (xReadyForMotion = TRUE).

Execution

With a rising edge (FALSEäTRUE) at the xMoveVelExecute input, the continuous travel is started on the basis of the parameters for the motion profile (see below). The technology module changes to the "MOVEVEL" state.

The axis travels until a software limit position has been reached or a hardware limit switch has been approached:

  • Input xDisableSWLimit = FALSE

  • Output xSwLimitEnabled = TRUE

  • Output xSwLimitSwitchPos/Neg = TRUE

  • Output xHwLimitSwitchPos/Neg = TRUE

When a software limit position has been reached, the axis is brought to a standstill via the lrDec parameter.

When a hardware limit switch has been reached, the axis is brought to a standstill via the QSP application deceleration ramp.

Then the state is changed back to "STANDBY".

Travel diagram

No

xMoveVel

Execute

xAbort

xFuncBusy

xFunDone

xConstant

Velocity

eTMState

Info

A

FALSEä TRUEæ FALSE

FALSE

FALSE ä TRUE

FALSE

FALSE

STANDBYW MOVEVEL

The axis accelerates to the target speed of 200 units/s.

B

FALSE

FALSE

TRUE

FALSE ä TRUE

FALSE ä TRUE

MOVEVEL

After reaching the target speed, xFunDone changes from FALSEäTRUE and xConstantVelocity changes from FALSEäTRUE.

C

FALSE

TRUE

TRUEæ FALSE

FALSEä TRUEæ FALSE

TRUEæ FALSE

MOVEVELW STANDBY

The speed run is terminated by xAbort = TRUE and brought to a standstill with the profile deceleration.

When standstill has been reached, xFunBusy is set = FALSE.

Parameters to be set

Further parameters for continuous travel can be found in the AXIS_REF in subindex 50 ... 53 and subindex 104 ... 105.