L_TW2P_scAP_WinderTensionCtrlState
Structure of the access points
The access points (AP) can be used to influence signals. In the initial state, the access points do not have any effect.
Each access point acts as an alternative branch and is activated via an OR operation or a switch.
|
Identifier Data type |
Description |
|
|---|---|---|
|
AP_xSetVelOffset BOOL |
Access point AP_lrVelOffset enabled |
|
|
TRUE |
Enable access point AP_lrVelOffset |
|
|
AP_lrVelOffset LREAL |
Cyclic specification of the offset for the velocity of the winder axis with regard to the winding shaft (gearbox output side)
The offset value is set immediately and abruptly without ramp generator! |
|
|
AP_xSetTrqOffset BOOL |
Access point AP_lrSetTrqOffset enabled |
|
|
TRUE |
The access point overwrites the values at the access point in the signal flow. |
|
|
AP_lrSetTrqOffset LREAL |
Cyclic specification of the offset for the torque of the winder axis with regard to the winding shaft (gearbox output side)
The offset value is set immediately and abruptly without ramp generator! |
|
|
AP_xSetVelOffsetDiamCalc BOOL |
Access point AP_lrVelOffsetDiamCacl enabled |
|
|
TRUE |
The access point overwrites the values at the access point in the signal flow |
|
|
AP_lrVelOffsetDiamCalc LREAL |
Cyclic specification of the offset for the velocity of the winder axis relative to the winding shaft (gearbox output side) for calculating the diameter
The offset value is set immediately and abruptly without ramp generator! |
|
|
AP_xSet BOOL |
Access point AP_lrSetSpeedPointDiamCalc enabled |
|
|
AP_lrSet LREAL |
Cyclic loading of speed setpoint for the drive
The offset value is set immediately and abruptly without ramp generator! |
|
|
AP_xSetAccCompTrq BOOL |
Access point AP_lrAccCompTrq enabled |
|
|
AP_lrAccCompTrq LREAL |
Resulting torque setpoint from the acceleration compensation of the winding drive
|
|
|
AP_xSetTrqPoint BOOL |
Access point AP_lrSetTrqPoint enabled |
|
|
AP_lrSetTrqPoint LREAL |
Alternative torque setpoint for the torque feedforward control.
|
|
|
AP_xSetUpperSpeedLimit BOOL |
Access point AP_lrSetUpperSpeedLimit enabled |
|
|
AP_lrSetUpperSpeedLimit LREAL |
Upper limit value for the speed limitation of the winding drive
|
|
|
AP_xSetLowerSpeedLimit BOOL |
Access point AP_lrSetLowerSpeedLimit enabled |
|
|
AP_lrSetLowerSpeedLimit LREAL |
Lower limit value for the speed limitation of the winding drive
|
|
|
AP_xSetFricCompReelSpeed BOOL |
Access point AP_lrSetFricCompReelSpeed enabled |
|
|
AP_lrSetFricCompReelSpeed LREAL |
Selection of the speed for the friction compensation
The corresponding torque for friction compensation is set in the unit [Nm] based on the speed AP_lrSetFricCompReelSpeed. |
|
|
AP_xDisableInternalControl BOOL |
TRUE |
Disable the InternalControl functionality of the technology module. If TRUE, the technology module cannot be controlled by the visualization template. |