L_TW2P_scAP_WinderTensionCtrlState

Structure of the access points

The access points (AP) can be used to influence signals. In the initial state, the access points do not have any effect.

Each access point acts as an alternative branch and is activated via an OR operation or a switch.

Identifier

Data type

Description

AP_xSetVelOffset

BOOL

Access point AP_lrVelOffset enabled

TRUE

Enable access point AP_lrVelOffset

AP_lrVelOffset

LREAL

Cyclic specification of the offset for the velocity of the winder axis with regard to the winding shaft (gearbox output side)

  • Unit: units/s

The offset value is set immediately and abruptly without ramp generator!

AP_xSetTrqOffset

BOOL

Access point AP_lrSetTrqOffset enabled

TRUE

The access point overwrites the values at the access point in the signal flow.

AP_lrSetTrqOffset

LREAL

Cyclic specification of the offset for the torque of the winder axis with regard to the winding shaft (gearbox output side)

  • Unit: Nm

The offset value is set immediately and abruptly without ramp generator!

AP_xSetVelOffsetDiamCalc

BOOL

Access point AP_lrVelOffsetDiamCacl enabled

TRUE

The access point overwrites the values at the access point in the signal flow

AP_lrVelOffsetDiamCalc

LREAL

Cyclic specification of the offset for the velocity of the winder axis relative to the winding shaft (gearbox output side) for calculating the diameter

  • Unit: units/s

The offset value is set immediately and abruptly without ramp generator!

AP_xSet
SpeedPointDiamCalc

BOOL

Access point AP_lrSetSpeedPointDiamCalc enabled

AP_lrSet
SpeedPointDiamCalc

LREAL

Cyclic loading of speed setpoint for the drive

  • Unit: rev/s

The offset value is set immediately and abruptly without ramp generator!

AP_xSetAccCompTrq

BOOL

Access point AP_lrAccCompTrq enabled

AP_lrAccCompTrq

LREAL

Resulting torque setpoint from the acceleration compensation of the winding drive

  • Unit: Nm

AP_xSetTrqPoint

BOOL

Access point AP_lrSetTrqPoint enabled

AP_lrSetTrqPoint

LREAL

Alternative torque setpoint for the torque feedforward control.

  • Unit: Nm

AP_xSetUpperSpeedLimit

BOOL

Access point AP_lrSetUpperSpeedLimit enabled

AP_lrSetUpperSpeedLimit

LREAL

Upper limit value for the speed limitation of the winding drive

  • Unit: revs/s

AP_xSetLowerSpeedLimit

BOOL

Access point AP_lrSetLowerSpeedLimit enabled

AP_lrSetLowerSpeedLimit

LREAL

Lower limit value for the speed limitation of the winding drive

  • Unit: revs/s

AP_xSetFricCompReelSpeed

BOOL

Access point AP_lrSetFricCompReelSpeed enabled

AP_lrSetFricCompReelSpeed

LREAL

Selection of the speed for the friction compensation

  • Unit: revs/s

The corresponding torque for friction compensation is set in the unit [Nm] based on the speed AP_lrSetFricCompReelSpeed.

AP_xDisableInternalControl

BOOL

TRUE

Disable the InternalControl functionality of the technology module. If TRUE, the technology module cannot be controlled by the visualization template.