L_TW2P_scSF_WinderTensionCtrlState

Structure of the signal flow

The content of the structure is read-only and offers a practical diagnostics option within the signal flow. (Signal flow diagram)

Identifier

Data type

Description

MP_lrWndVelRef

LREAL

Nominal speed of the reel (output end)

  • Unit: unit/s

MP_lrWndSpeedRef

LREAL

Reference of the winder speed at minimum diameter and maximum line velocity.

  • Unit: rev/s

The reference speed of the winder is calculated as follows:

The reference values for the calculation of MP_lrWndVelRef and MP_lrWndSpeedRef are lrMinDiam and lrLineVelRef from the parameter structure scPar.

MP_liRevCounter

LREAL

Counter content of the material length counter (whole numbers of complete reel revolutions)

MP_lrRevCounterResidual

LREAL

Counter content of the material length counter (residual value after one complete reel revolution)

  • Unit 1 x 100 %

  • 100 % = One reel revolution

MP_lrAxisSpeed

LREAL

Current speed of the reel (output end)

  • Unit: rev/s

MP_xDiamCalculated

LREAL

FALSEรคTRUE edge: The diameter has been calculated. The measuring point is only set to TRUE for one PLC cycle

MP_lrSetDiamUnfiltered

LREAL

Current diameter calculated

  • Unit: mm

MP_lrSetDiamAdapted

LREAL

Diameter resulting from the lrSetDiam input.

  • Unit: mm

MP_lrSetDiamScaledOut

LREAL

Scaled diameter resulting from the lrSetDiam input.

  • Unit: 1 x 100 %

  • 100 % lrMaxDiam

MP_lrSetLineVelScaledOut

LREAL

Scaled line speed

  • Unit 1 x 100%

  • 100% lrLineVelRef

MP_lrActTotalTrqScaled

LREAL

Torque calculated from the measured current (scaled)

  • Unit x100 %

  • 100% nominal torque

MP_lrTensCurveOut

LREAL

Tensile force setpoint evaluated using characteristic function.

  • Unit: N

MP_lrSetTensPoint

LREAL

Filtered tensile force setpoint with characteristic function evaluation

  • Unit: N

MP_lrSetTensTrq

LREAL

Torque calculated from the tensile force setpoint

  • Unit: Nm

MP_lrAccCompTrq

LREAL

Torque resulting from acceleration compensation

  • Unit: Nm

MP_lrSetFricCompTrq

LREAL

Torque resulting from friction compensation

  • Unit: Nm

MP_lrSetTrqPoint

LREAL

Resulting torque for reels

  • Unit: Nm

MP_lrSetUpperSpeedLimit

LREAL

Upper limit value for limiting reel speed

  • Unit: rev/s

MP_lrSetLowerSpeedLimit

LREAL

Lower limit value for limiting reel speed

  • Unit: rev/s

MP_lrAxisUpperSpeedLimit

LREAL

Upper limit value for limiting reel speed

  • Unit: units/s

MP_lrSetSpeedPoint

LREAL

Resulting speed setpoint

  • Unit: rev/s

MP_lrAxisLowerSpeedLimit

LREAL

Lower limit value for limiting reel speed

  • Unit: units/s

MP_lrAxisVel

LREAL

Reel speed (output end)

  • Unit: unit/s

MP_lrAxisTorque

LREAL

Reel torque (output end)

  • Unit: Nm

MP_lrSetTensScaledOut

LREAL

Scaled tensile force setpoint

  • Unit x 100 %

  • 100 % = scPar.lrTensRef

MP_lrSetTensTrqScaledOut

LREAL

Scaled torque calculated from the tensile force setpoint

  • Unit x 100%

  • 100% = Rated torque

MP_lrSetFricTrqScaledOut

LREAL

Scaled torque pre-control value of friction compensation

  • Unit x 100 %

  • 100 % = Nominal torque

MP_lrAccTrqScaledOut

LREAL

Scaled torque pre-control value of acceleration compensation

  • Unit x 100 %

  • 100 % = Rated torque

MP_lrFiltActTensIn

LREAL

Filtered tensile force from the lrActTensIn input

MP_lrTensCtrlOut

LREAL

Correcting variable from tensile force controller

MP_lrTensCtrlOutGain

LREAL

Correcting variable of the proportional component (P component) of the tensile force controller

  • Unit: N

MP_lrTensCtrlOutResetTime

LREAL

Correcting variable of the proportional component (I component) of the tensile force controller

  • Unit: N

MP_lrTensCtrlOutRateTime

LREAL

Correcting variable of the proportional component (D component) of the tensile force controller

  • Unit: N

MP_lrTensCtrlOutScaled

LREAL

Scaled correcting variable from tensile force controller

  • Unit: x 100 %

  • 100 % = lrTensRef

MP_lrSetTensCtrlValue

LREAL

Setpoint for the PID tensile force controller

  • Unit: N

MP_lrActTensCtrlValue

LREAL

Actual value for the PID tensile force controller

  • Unit: N

MP_lrActTensScaled

LREAL

Scaled current tensile force

  • Unit: x 100 %

  • 100 % lrSetTens

MP_xLineStandStill

BOOL

TRUE

Standstill of the line was detected.

MP_lrDistToLineStop

LREAL

Calculation of the distance in the technology module that initiates the braking phase of the line so that the winder reaches the material length lrTargetMaterialCounter.

  • Positive value

    • Distance until the braking phase of the line is initiated with the parameters lrSyncLineDec and lrLineJerk.

  • Negative value

    • Distance reached by the target over the length lrTargetMaterialCounter when the braking phase of the line is initiated with the parameters lrSyncLineDec and lrLineJer.

MP_lrTargetMaterialCounterStopLine

LREAL

Display of the counter reading of the material length counter when the braking phase of the line is initiated with the parameters lrSyncLineDec and lrLineJerk.

MP_xInternalControlActive

BOOL

The technology module is currently controlled by the InternalControl functionality (visualization template). Commands from the tm interface are ignored.